background image

8/12 

www.qundis.com Network 

nodes 

with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009 

State of the 
system  

Display 

Explanation 

Remote  
access 

C

During remote access the symbol ‚ ’ will be displayed. 

Highspeed-
mode 

for example 

M

When all network nodes have switched on their receivers for 
fast data exchange, this will be displayed as two dots in the 
upper part of the LCD. 

Bus-connection 
(from version 
2.2) 

for example 

 

If a connection to a bus is being built up, the number of 
the bus and the primary address of this bus will be 
briefly displayed . 
In the example, network node 03 is connected to M-
BUS 

IrDA-master 
mode (from 
version 2.2) 

This mode is started by pressing the button MODE. (< 
0,5 sec). It indicates readiness to connect additional 
IrDA devices (in IrDA Slave mode). This mode stops 
after 10 sec. 

Add (from 
version 2.2) 

for example 

 

If an unregistered IrDA-capable metering device (e.g. 
WHE467) is connected in IrDA master mode, it can be 
inserted into the network node by pressing the button 
DISPLAY while ADD is displayed. The last 4 digits of device 
number are indicated. (e.g. 20000123). 
The registration of the device takes place and search mode 
starts.  

Delete (from 
version 2.2) 

for example 

 

If an already registered IrDA-capable metering device is 
connected in IrDA-master mode it can be removed from
the network node by pressing the button DISPLAY while 
DEL is displayed. The last 4 digits of device number are 
indicated (e.g. 20000123). 
The removal of the device takes place and if necessary 
search mode is stopped. 

Copy (from 
version 2.2) 

for example 

 

 

If a new network node (running in idle mode) is connected in 
IrDA-master mode, it is possible to make a copy of all net-
work data into the new node by pressing the button 
DISPLAY while COPY is displayed. 
Copying lasts up to 20 minutes. At the end "StArt Prot" is 
displayed on LCD of the new network node for 1 hour. After 
mounting the new node the protected mode is also started 
by pressing the DISPLAY button. By this procedure the new 
network node is integrated in network and search mode is 
started automatically. 

Engineering notes 

For detailed engineering instructions, refer to the QUNDIS Engineering Manual CE1J2870. 
 

Commissioning of WTX.. 

For mains-powered WTX16.... network nodes, the mains connections are to be made first at 
the selected mounting positions (typically on every second floor, mounting height 

 2 m). 

Engineering 

Summary of Contents for WTX16.GSM

Page 1: ...been designed for use in buildings to create a radio network for receiving and storing the data transmitted by the consumption meters installed in the building Communication between several net work n...

Page 2: ...ster Max number of meters WTX16 GSM Network node with gateway remote readout via GSM yes 5 additional unit loads 2000 WTX16 IP Network node with gateway remote readout via Ethernet yes 5 additional un...

Page 3: ...ay to store data of up to 2000 meters and to provide a possibility for remote readout via GSM or Ethernet The gateway has an additional M Bus master that can drive up to 5 additional external M Bus un...

Page 4: ...electrical connections are made The electronics section is identical for all types of network nodes It contains control ele ments of the network RESET MODE DISPLAY 1 2 3 4 6 7 11 10 8 9 5 1 Connector...

Page 5: ...y DC 3 6 V 2 Indication of mains supply red LED 3 permanently installed cable no flexible cable 4 SIM card holder WTX16 GSM only 5 RS232 interface for servicing 6 Connector for M bus service connectio...

Page 6: ...red LED 3 permanently installed cable no flexible cable 4 SIM card holder WTX16 MOD only 5 RS232 interface for servicing 6 Connector for M bus service connection 7 Anschluss f r M Bus 8 mains connect...

Page 7: ...It can also be started manually with the ACT26 service tool Installa tionsmode2 In installation mode the radio network will be built up automati cally Metering devices that transmit installation tele...

Page 8: ...The registration of the device takes place and search mode starts Delete from version 2 2 for example If an already registered IrDA capable metering device is connected in IrDA master mode it can be r...

Page 9: ...ss II Then the live L and neutral N conductors must be connected to terminal IN of the power pack Mains voltage must be in the range from AC 100 to 240 V 50 60 Hz There is no protective earth PE conne...

Page 10: ...for voice and data service SIM cards only sold for voice service or M2M service cannot be used For that purpose remove the upper section of the WTX16 GSM from the base Press the SIM card slightly in...

Page 11: ...tained Staff dealing with the product must be familiar with all potential hazards and maintenan ce measures in accordance with the instructions given in this document It must be possible to disconnect...

Page 12: ...cy of transmission 1 Permanent ambient temperature Transport and storage Operation 20 60 C 30 C recommended 0 55 C Weight 0 3 kg Dimensions 184 31 8 9 7 200 6 0 R 1 5 0 R 100 150 250 2 5 0 R 55 250 2...

Reviews: