QM1014 LO Synthesizer Distribution Unit
User Manual
3. POWEr Subsystem Command Reference
3.1 POWEr:RF [ON
|
OFF
|
1
|
0]
This command allows the user to turn on and off the RF power of the QM1014.
When
0
or
OFF
is specified, the RF power is turned off.
When
1
or
ON
is specified, the RF power is turned on.
Syntax
:
POWE
:
RF
Space
"ON"|"OFF"|1|0
?
Example
:POWE:RF 0
This command turns off the RF power.
Default Condition
On power up, or when a
*RST
command is issued, the QM1014 returns to the boot state’s setting. The
LO Synthesizer Distribution Unit default setting is 0.
Query
:POWE:RF?
This query returns a 0 or 1 to indicated the LO Synthesizer Distribution Unit power state.
∙
0
is returned if the RF power is
OFF
∙
1
is returned if the RF power is
ON
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
Quonset Microwave
Revision 1.2.1