GRB-200 Demodulator (GOES-R) OI&M
GRB-200 Demodulator (GOES-R) OI&M
© Copyright 2015, Quorum Communications, Inc.
Revision A.01
42
<FEED>
<Power val=" ON"/>
<Current val="52mA"/>
<Overcur val="No"/>
<Comm val="OK"/>
<Serialno val="150101"/>
<Voltage val="23.4VDC"/>
<LOlock val="LK"/>
<Temp val="38C"/>
<Hum val="35%"/>
<Press val="0.4PSI"/>
<Purge val="OPEN"/>
</FEED>
This section reports the status of the GRB Feed. The first 3 values report the
power status of the feed as provided by the GRB Demodulator. These include
the power status, turned ON or OFF, the current being drawn and if the over-
current circuit is active. If the feed draws too much current, power will be
temporarily removed from the feed. After 10 seconds the GRB Demodulator
will reapply power and attempt to restart the feed.
After this, the value Comm reports that the GRB Demodulator is (OK) or is not
(NO) receiving status data from the GRB Feed.
If the GRB Demodulator is receiving status data from the feed, then the
following fields, Serial number (Serialno), feed voltage (Voltage), feed local
oscillator status (LOlock), feed internal temperature (Temp), feed internal
humidity (Hum), feed internal pressure (Press) and purge valve status (Purge)
will be fill with valid data. Otherwise these fields will be NULL.
To receive the status data, connect the gigabit Ethernet port of the GRB
Demodulator to your Data Processing Server and read it from the appropriate
UDP port.