Fig. 7

Downrod 

Hanger bracket

WARNING -

Turn off the power!

DO NOT fasten the blades to the fan until 

it is assembled and hanging from the 

ceiling.  To do so now will likely bend the 

blade arms and almost certainly cause 

wobble.

CAUTION: Remove 4 rubber packing 

mounts from fan motor assembly and 

discard before installation.

1.

If not already affixed to the hanger

bracket, place the rectangular rubber isolators 
between the hanger bracket and outlet box.  
Secure the hanger bracket to the outlet box 
using the 2 long steel screws supplied with 
the outlex box.

2.

Remove the set pin and safety lock clip

from the yoke on top of the motor assembly.  
Slide the downrod through the canopy and 
canopy cover. Slide the yoke cover onto the 
downrod (Fig. 5).  Feed the wires from the 
fan motor through the downrod assembly.

3.

(Fig. 6) Attach the downrod assembly

(downrod, yoke cover, canopy and canopy 
cover) to the motor by sliding the downrod 
into the yoke on top of the motor assembly. 
Slide the set pin through the hole in the yoke, 
downrod and secure it with the safety lock 
clip.  Tighten the set screws on yoke.  The 
yoke cover will lower down to conceal the 
yoke.  Feed the wires through the downrod 
ball. 

4.

Lift the fan motor without the blades and

place into the hanger bracket, rotating the 
ball until the groove engages the tab on the 
hanger bracket.  This locks the ball mount 
and fan motor, preventing fan rotation during 
operation. (Fig. 7)

4. HANGING YOUR FAN

Fig. 5

Downrod 
assembly

Ceiling
canopy

Canopy
cover

Yoke cover

Fig. 6

Downrod 

Set screw

Yoke

Safety 
lock clip

Set pin

Canopy

Canopy cover

Yoke cover

Summary of Contents for PROXIMA PATIO

Page 1: ...wing QUORUM INTERNATIONAL fans Proxima Patio 60 72 P O Box 961008 Fort Worth TX 76161 817 626 5483 FAX 817 626 5540 I0228 07 15 2015 Quorum International All Rights Reserved Please read and save these...

Page 2: ...stions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Lig...

Page 3: ...lation or before servicing the fan or installing accessories 2 Read all instructions and safety information carefully before installing your fan and save these instructions 3 Make sure all electrical...

Page 4: ...blade clearance 5 To hang the fan in locations where no ceiling joist is available a hanger support bar may be required Figure 4 Quorum distributes approved hanger support bars and outlet boxes 3 MOU...

Page 5: ...er Slide the yoke cover onto the downrod Fig 5 Feed the wires from the fan motor through the downrod assembly 3 Fig 6 Attach the downrod assembly downrod yoke cover canopy and canopy cover to the moto...

Page 6: ...Y from the transmitter to the remaining BLACK wire from the wall A C supply source If your junction box has a ground wire green or bare copper connect the transmitter s ground wire to it Otherwise con...

Page 7: ...the blade and motor and secure with screws and blade support plate Repeat process with the other blades Fig 10 DO NOT bend the blade arms when installing the blades 3 Attaching the Motor Bottom Housin...

Page 8: ...ep 3 The fan will start to run and begin the control setting process The fan will run in both directions for a total of approximately 5 minutes Step 4 When the fan stops after approximately 5 minutes...

Page 9: ...Periodically check tightness of all screws securing the blades to the blade arm attachment points A clicking or a rattling noise is a sure indication of loosening screws Since screws will invariably w...

Page 10: ...trol to control the fan speed will always cause an annoying hum Many fan motors do not work quietly with solid state variable speed controls 4 Check that the rubber gasket on the mounting bracket has...