FAN WILL NOT START
1.

   Check that the electricity has been 

turned on at the circuit breaker which had 
probably been turned off during 
installation.

2. 

  Turn off the electricity.  Check all 

connections in the wiring of the fan at the 
ceiling and make sure it follows the 
wiring instructions outlined in this 
manual.

NOISE
Note:

 Always allow a day or two "run-in" 

time for any new fan at medium or high 
speed.  When attempting to diagnose 
noise, listen carefully from several sides 
to try and isolate the location of the noise 
(blade, upper end, motor, light kit, etc.)

1.   

Tighten all screws attaching blades to 

blade arms.  Remember to tighten these 
screws at least once a year because they 
may loosen slowly over time and cause a 
clicking noise.

2. 

  Turn off the power.  Loosen the 

canopy and check that the wiring and/or 
wire nut connectors are not resting against 
the canopy, possibly vibrating while the 
fan is on.

3.

   Use of a standard light rheostat or an 

unapproved fan wall control to control the 
fan speed will always cause an annoying 
"hum".  Many fan motors do not work 
quietly with solid state variable speed 
controls.

4.

   Check that the rubber gasket on the 

mounting bracket has been installed if 
called for in the installation instructions.

5.

   Check that the canopy in not touching 

the ceiling.

6. 

  Check that all screws on the motor 

housing and the bottom housing are tight.

FAN TURNS, BUT DOES NOT MOVE 
MUCH AIR
1.   

The fan may be running in reverse. 

The reverse switch located on the control 
cup. (see Fig. 15)

2. 

  The distance from the ceiling to the 

blades may be too small.  For downrod 
fans, optimal placement would be 8-9 feet 
from the floor.

3.

   The room may contain items which 

obstruct the air flow.

4. 

  The fan may be too small for the size 

of the room.

EXCESSIVE WOBBLE 
Note: 

A small amount of wobble is 

considered acceptable and should not be 
considered a defect.

1. 

  Make certain all blades are tightly 

attached to each blades' respective blade 
arm.

REPLACEMENT PARTS AVAILABLE

A full range of genuine replacement 
spare parts are available at reasonable 
cost directly form Quorum 
International.  Please call us at (817) 
626-5483.  Monday through Friday 
from 8:00 A.M. to 5:00 P.M. CST.

8. TROUBLESHOOTING

Fig. 15

Reverse 
switch

Summary of Contents for The Chateaux 52"

Page 1: ...ns are to be used in the installation of the following QUORUM INTERNATIONAL fans The Chateaux 52 60 Uni Pack 2014 P O Box 961008 Fort Worth TX 76161 817 626 5483 FAX 817 626 5540 IO221 03 14 THE CHATE...

Page 2: ...stions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Lig...

Page 3: ...l before you begin the fan installation or before servicing the fan or installing accessories 2 Read all instructions and safety information carefully before installing your fan and save these instruc...

Page 4: ...blade clearance 5 To hang the fan in locations where no ceiling joist is available a hanger support bar may be required Figure 4 Quorum distributes approved hanger support bars and outlet boxes 3 MOUN...

Page 5: ...the yoke on top of the motor assembly Slide the downrod through the canopy Fig 5 Feed the wires from the fan motor through the downrod assembly 3 Fig 6 Attach the downrod assembly downrod and canopy t...

Page 6: ...the white white and green copper connections are on the other side Use the wire nuts supplied with your fan when making connections Secure the connectors with electrical tape and make sure there are...

Page 7: ...mbly under your fan snap together the wire connection plugs Carefully push all wires back into the control cup then install the light kit assembly onto the control cup plate with 3 screws provided Be...

Page 8: ...Periodically check tightness of all screws securing the blades to the blade arm attachment points A clicking or a rattling noise is a sure indication of loosening screws Since screws will invariably w...

Page 9: ...always cause an annoying hum Many fan motors do not work quietly with solid state variable speed controls 4 Check that the rubber gasket on the mounting bracket has been installed if called for in the...