background image

Page 8 

OPTIONS 

 

OVERVIEW

  

 

 The CGC-1e can be upgraded and expanded by using our expansion devices including the UPM-1, MLC-4 or the precision 
PPM-1c. The Universal Power Modules and Master Light Controllers allow you to run multiple pumps, fans and lights by 
controlling remote relays. The PPM-1c allows you to control CO

2

 with Part-Per-Million accuracy! 

 

  
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

 
 
 

 

  

UNIVERSAL POWER MODULE (UPM-1)

 

 

 

The UPM-1 Universal Power Module is a unique device that can allow the user to run 

additional HID lights or control multiple fans / air conditioners etc. 
 The UPM-1’s “plug-box” was designed to be plugged into a standard household outlet.  
The 16-foot long “trigger cable” coming from the UPM-1 is then connected to your 
control device such as a time clock or thermostat. When the control device turns ON, the 
relay inside the UPM-1 box applies power to the twin outlets on the front of the UPM-1 
turning ON whatever is plugged into it.  This allows you to run additional lights etc. 
from a different circuit with one common control device. 
The UPM-1 is rated at 15-amps @ 120 volts. 

PART-PER-MILLION CO

2

 SENSOR (PPM-1c)

 

 
 To take full advantage of supplemental CO

2

, you must be able to precisely control the 

level of CO2. This is made possible by plugging in our “CO

2

 Controller”, the 

PPM-1c

The 

PPM-1c 

controller is constantly sampling the level of CO

2

 in the growing area and 

can measure from 0 to 5000 PPM. The 

PPM-1c

 displays the current CO

2

 level in PPM 

using large a 4-digit LED display. It then transmits that information to the CGC-1e.  
 The PPM-1c is powered by a 18-24volt power supply. 

MASTER LIGHTING CONTROLLER (MLCs)

 

 
The MLC-4 and MLC-4a Master Lighting Controllers are the best devices for 
controlling up to (4) HID lights from one time clock or controller. Like the HPR-1, 
power must be brought into the “input” side of the control relay. The MLC-4 features (4) 
standard 240v outlets, which your ballasts are plugged into. The MLC-4a is designed for 
120 volt ballasts however it can also be used to run ballasts wired for 240-volt operation, 
which have 120-volt power cords. The MLC-8 Master Lighting Controller is the best 
device for controlling up to (8) HID lights from one time clock or controller.  Power is 
brought into the MLC-8 by hardwiring up to a 40-amp circuit. The MLC-8 features (8) 
standard 240v outlets, which your ballasts are plugged into. 
The MLCs both feature a 120-volt trigger cable to plug into a standard 24-hour timer or 
controller.  The MLC-4 & MLC-4a are rated 30-amps @120/240 volt. The MLC-8 is 
rated at 40-amps @ 240 volt. 

HID LIGHTING CONTROLLER (HLC-2e) 

 
The HLC-2e HID lighting controller was primarily designed to protect your expensive 
HID lights from HOT-STARTS. 
 A “Hot-Start” occurs whenever your lights are turned off… and then back on before the 
lamps are allowed to cool off. Hot-starts caused by power outages reduces your lamp’s 
life and intensity. It can be plugged into either of the “Lights” outlets. 
 When the HLC-2e is connected to your lights, it will sense a power interruption, and 
start a 15-minute time-delay to keep the lights from trying to re-fire while the cool down. 
The HLC-2e can also be used to delay other devices from starting. 
The HLC-1e is rated for 15-amps @ 120volts. 
 

 

 

 

Summary of Contents for CGC-1e

Page 1: ...arranty All components are warranted by R M Supply against defects in workmanship and materials under normal use for 3 years from the date of purchase The CGC 1e is 100 maintenance free and does not r...

Page 2: ...ller CO2 ON timer Optional PPM 1c quick connect Hydro OFF timer 2 Light outlets CO2 OFF timer Hydro mode selector switch Temperature controller 2 Hydro pump outlets Fuse protected 15 amps 120 volts Co...

Page 3: ...t control the CGC 1e refer to the Timers section of this manual Set the Hydro and CO2 timers to your desired settings before continuing Refer to Timers 8 The 24 hour timeclock can now be set Push in t...

Page 4: ...reatest accuracy provide the CGC 1e with plenty of fresh air The enclosure is designed to allow air to pass over the humidity sensor HUMIDITY CONTROLLER The CGC 1e utilizes a de humistat to control ve...

Page 5: ...t the Hydro and CO2 timers correctly HYDROPONICS TIMERS The Hydroponic outlet can be configured to cycle one of two ways 24 hours a day or during the daytime only Simply moving the Hydro Mode selector...

Page 6: ...t being drawn out of the area by the ventilated hood exhaust fan If sufficient CO2 is provided and the proper level of nutrients and light is available a 35 increase in growth rate is possible However...

Page 7: ...e PPM 1c controller consists of an infrared detector capable of measuring atmospheric CO2 levels from 0 to 5000 PPM The PPM 1c is powered by an 18 vdc to 24vac power supply When it is connected it wil...

Page 8: ...ation to the CGC 1e The PPM 1c is powered by a 18 24volt power supply MASTER LIGHTING CONTROLLER MLCs The MLC 4 and MLC 4a Master Lighting Controllers are the best devices for controlling up to 4 HID...

Page 9: ...ems to be quite high Make sure your area is sealed You may want to install a motorized damper to seal your exhaust fans when they are OFF Even though the CGC 1e operates a standard timed release seque...

Page 10: ...lbs Relay operations Minimum 100 000 electrical 10 000 000 mechanical MAINTENANCE 1 Consult the troubleshooting chart for a listing of the most common problems 2 DO NOT open the enclosure There are no...