21
BA_BM_HS-2000_EN_46-21.docx
11
Troubleshooting
Repair and maintenance work may only be carried out by competent, trained and instructed personnel.
Repair work on mechanical and hydraulic components may only be carried out by
authorised and trained personnel.
Proceed systematically when searching for the cause of a malfunction. If you are unable to find the fault or to
remedy the malfunction, contact our customer service department (phone: 0049 7576 / 962 978 - 0).
Before you call us, please follow these steps:
•
Make a note of the information on the nameplate of your lift table (see
•
Keep these operating instructions and any supplementary documents at hand.
The more precisely you describe the fault to us, the better we can then remedy the situation.
General Faults
Fault
Possible Cause
Remedy
Lift table does not lower
completely to the bottom
Safety catch for maintenance is locked
→
Lift the platform little upwards
and unlock the safety catch
Object stuck in lift table scissors
→
Remove object
Platform cannot
be lifted up
Lift table is overloaded
→
Reduce load
Hydraulic cylinder, foot pump
or mechanics defective
→
Contact customer service
Faults with Model HS 2000 | AH
Fault
Possible Cause
Remedy
The lift table cannot be
adjusted in height
Battery empty
→
Charge battery
Push button unit or cable defective
→
Contact customer service
Battery or component in box defective
→
Contact customer service
Battery cannot
be charged
CTEK charger or cable defective
→
Contact customer service
Battery defective
→
Contact customer service