20
BA_BM_HS-600_EN_45-21.docx
10
Measures after Operation
10.1
General Measures
Additional electrical components (e.g. machines lying on the lift table) must be switched off after finishing work
and also disconnected from the mains by unplugging the power cable. Furthermore, the lift table must be se-
cured against unauthorised use. The following options are available for this purpose:
•
Lock away or park in such a way that unauthorised persons have no access to the lift table.
•
Secure the lift table by means of a lock chain or wire rope to prevent unauthorised movement.
•
Place a prohibition sign on the platform to prevent unauthorised use.
•
For battery-operated hydraulic AH models, pull off the main switch handle
(see next section
10.2
Measures for battery-hydraulic Models (AH)
After the lift table platform has been lowered completely and the applied load has been removed
→
Switch off the battery hydraulics vie the main switch (10)
→
Connect the charging cable of the battery charger to 230 VAC
(charging is also possible when the main switch is turned off).
A well and fully charged battery allows effective operation throughout the working day.
To prevent unauthorised use of the lift table, the rotary handle of the main switch (
10
) can easily be pulled off.
The procedure is as follows:
Figure 8: Secure main switch
•
Move the main switch handle to the "
OFF
" position by turning it in the
direction of the arrow shown in
•
Then turn the main switch handle again by approx. 45° in the same di-
rection (against a slight resistance).
•
Now the main switch handle can be removed to the front.
To replace the main switch handle, reverse the previous procedure. After
the coded installation, the main switch handle must be pressed against the
housing before it is turned.
10
The lift table should not be used while the batteries are charging.