- 18 -
K10-STANDARD-OP-EN
VACUUM MOTOR:
1. The machine is equipped with a 24 volt,
.75HP Vacuum Motor
(A)
(SEE BELOW)
.
2. If foam or water gets past the Recovery Tank’s
Vac Screen/Ball system, adjust the bracket
(B)
in the Tank upwards
(SEE BELOW)
.
3. The Vacuum Motor has an
(standard)
“Foam Muffler”
(C)
, sound reduction walls
(D)
and vibration dampeners
(E)
that are
available to quiet machine operation.
SOLUTION FILTER:
The solution system has an “Inline Filter”
(A)
to filter out
cleaning solution prior to scrubbing
(SEE BELOW)
.
CLEANING SOLUTION FILTER:
1. To clean the Solution Filter, first close Solution Flow
Valve by moving lever
(B)
down. Then unscrew
the clear cap
(C)
from house
(A)
and remove
the stainless steel screen
(E)
(SEE BELOW)
.
2. Rinse any debris from the screen with clean water.
3. Reinstall screen and screw cap back on tightly.
4. Re-open valve.
B
C
D
A
E
D
B
A
E
C