1. Keep the welder input power lines as short as possible and enclose as much of them as
possible in metal conduit or equivalent shielding. There should be a good electrical
contact between this conduit and ground (Earth).
2. Keep the work and electrode leads as short as possible. Tape the leads together where
practical.
3. Be sure the torch and earth leads rubber coverings are free from cuts and cracks that allow
welding power leakage
4. Keep earth lead connection to work in good condition – Clean area on workbench where
earth clamp is situated on a regular basis.
Input Connections
Make sure the voltage, phase and frequency of input power is as specified on machine rating
plate located at rear of machine.
Have a qualified electrician provide suitable input power as per national electrical codes. Make
sure machine is earthed / grounded.
Make sure fuse or circuit breaker is correct rating for machine. Using fuses or circuit breakers
smaller than recommended will result in ‘nuisance’ shut off from welder inrush currents even if
welding at low amperages.
Failure to follow these instructions can cause immediate failure within the welder and void
machines warranty.
Turn the input power OFF at the mains switch & fuse box before working on this equipment.
Have a qualified electrician install & service this MIG welding equipment.
Allow machine to sit for 5 minutes minimum to allow the power capacitors to discharge before
working inside this equipment. Do not touch electrically live parts
The IMIG 160 MIG Welder requires a 240V 50/60Hz 1-Phase supply. It requires a 13A supply. It
comes with a 3 metre mains cable attached.
Connect wires according to national coding.
Brown wire – Live
- Blue wire – Neutral -
Green/Yellow Wire – Earth (Ground)
Connecting to an Engine Driven Generator
If connecting this machine to an engine driven generator please ensure the
following
Minimum Generator KVA Output – 4.8 KVA continuous
Generator to be fitted with AVR (automatic voltage regulation
)
DO NOT USE ON A GENERATOR WITHOUT AVR. Connecting to a
generator without the above minimum requirements will in-validate your
warranty