Operating the Machine in MMA mode
Connect the following:
1.
Negative welding power connector
Connect the earth cable dinse plug into here and twist to secure
2.
Positive welding power connector
Connect the electrode holder cable dinse plug into here and twist to secure
Most popular rods have a positive welding electrode and negative earth. If you are using
special electrodes check the manufacturer’s recommendation for correct polarity of welding
electrodes and connect as required.
1. Ensure machine is setup as previously stated
2. Fit desired electrode size in electrode holder
3. Switch on machine
4. Set Mig/MMA switch to MMA position
5. Select desired welding power
6. Touch electrode on to workpiece and the arc will start
When the machine is switched on, output terminals are always live, take care and do
not touch electrode and earth by person at same time, otherwise an electric shock will
occur.
Maintenance
Routine and periodic maintenance
WARNING!
ELECTRIC SHOCK CAN KILL
Turn the input power OFF at the mains switch & fuse box and remove mains plug from socket
before working on this equipment.
Have a qualified electrician install & service this equipment.
Allow machine to sit for 5 minutes minimum after disconnection from mains power to allow the
power capacitors to discharge before working inside this equipment.
Do not touch electrically live parts
1. Periodically (3-6 months depending on use / environment), remove the side/top panels
of machine and clean out machine with a low pressure dry air line paying particular
attention to PC Boards, Fan blades and switchgear Failure to maintain plant can void
manufacturer’s warranty.
2. Inspect input and output cables & hoses for fraying and cuts, replace if damaged
present
3. Keep the MIG torch and earth cables in good condition
4. Clean the air vents to ensure proper air flow and cooling
5. The fan motor has sealed bearings which requires no maintenance