11
Controls and Settings
Fig 4
1.
Base current control
This adjusts the main welding current and is shown in L.E.D (Fig 4.11)
2.
Pulse peak current adjustment
This sets pulse amperage and must be set above the base (main) current amperage. If set
to zero pulse welding is disabled.
3.
LED Display
3 digit LED meter is used to display the pre-set (before welding) amperage and actual
amperage (when welding).
4.
AC squarewave balance (SP%)
SP% AC Squarewave balance control 30% – 70%
Set at 50% this provides balanced control suitable for most AC Welding. 30% is max
cleaning and 70% is max penetration.
When welding dirty/contaminated material more cleaning may need to be selected.