II. Over Reflected Power
Reflected power alarm display.
Stop 2
III. Over Input Power
Input power alarm display.
Stop 3
Once the machine goes into “FAULT” mode, it will no longer attempt to re-start;
choose the appropriate reset procedure according to current machine setting:
• Machine set to LOCAL control mode - press “Reset Alm” in the alarm menu
(menu 7) or power off and back on again using the POWER switch (chap.
6.2).
• Machine set to REMOTE control mode - power off and back on again sending
the appropriate command via the DB15 connector (chap. 6.3.2 - item [14] and
[15]).
There is a fourth alarm that does not trigger a “FAULT” condition, but allows some
time until correct operating conditions are restored. When the temperature alarm
threshold is exceed (about 85°C), the following screen appears:
4. Over Temperature
Temperature power threshold exceeded.
Alarm 4