background image

1 / 14

User Manual

Rev. 1.0- 16/11/07

GPSRXNV-01

 

1.  Preliminary Instructions

• General foreword

The  equipment  in  object  is  to  considering  for  uses, 

installation  and  maintenance  from  “trained”  or  “qualified” 

staff,  they  conscious  of  the  risks  connected  to  operate 

on electronic and electrical circuits electrical.   

 

The  “trained”  definition  means  staff  with  technical 

knowledge  about  the  use  of  the  equipment  and  with 

responsibility  regarding  the  own  safety  and  the  other 

not  qualified  staff  safety  place  under  his  directed 

surveillance in case of works on the equipment.   

 

The “qualified” definition means staff with instruction and 

experience  about  the  use  of  the  equipment  and  with 

responsibility regarding the own safety and the other not 

qualified staff safety place under his directed surveillance 

in case of works on the equipment. 

  WARNING:  The  machine  can  be  equipped  with 

an ON/OFF switch which could not remove completely 

voltages  inside  the  machine.  It  is  necessary  to 

have  disconnected  the  feeding  cord,  or  to  have 

switched  off  the  control  panel,  before  to  execute 

technical  operations,  making  sure  himself  that  the 

safety connection to ground is connected. 

 

The technical interventions that expect the equipment 

inspection with circuits under voltage must be carry out 

from trained and  

qualified  staff  in  presence  of  a 

second  trained  person  that  it  is  ready  to  intervene 

removing voltage in case of need.
R.V.R. Elettronica SpA

 doesn’t assume responsibility for 

injury  or  damage  resulting  from  improper  procedures  or 

practices by untrained/unqualified personnel in the handling 

of this unit.

 WARNING: The equipment is not water resistant 

and  an  infiltration  could  seriously  compromise 

its  correct  operation.    In  order  to  prevent  fires  or 

electric shocks, do not expose the equipment to rain, 

infiltrations or humidity.

Please observe all local codes and fire protection standards 

during installation and use of this unit.

  WARNING:  The  equipment  has  to  its  inside 

exposed  parts  to  risk  of  electric  shock,  always 

disconnect power before opening covers or removing 

any part of this unit.

Fissures and holes are supplied for the ventilation in order 

to assure a reliable efficacy of the product that for protect 

itself from excessive heating, these fissures do not have 

to be obstructed or to be covered. The fissures doesn’t be 

obstructed in no case.  The product must not be incorporated 

in a rack, unless it is supplied with a suitable ventilation or 

that the manufacturer’s instructions are been followed.

  WIRING:  This  equipment  can  irradiate  radio 

frequency  energyand  if  it’s  not  installed  following 

the  instructions  contained  in  the  manual  and  local 

regulations  it  could  generate  interferences  in  radio 

communications.

 WIRING: This device has a connection to ground 

on the power cord and on the chassis.  Check that they 

are correctly connected.

Operate with this device in a residential ambient can cause 

radio disturbs; in this case, it can be demanded to the user 

to take adequate measures.

Specifications and informations contained in this manual  

are furnished for information only, and are subject to change 

at  any  time  without  notice,  and  should  not  be  construed 

as a commitment by 

R.V.R. Elettronica SpA

 

The 

R.V.R. Elettronica SpA

 assumes no responsability or 

liability for any errors or inaccuracies that may appear in 

this manual, including the products and software described 

in it;and it reserves the right to modify the design and/or 

the technical specifications of the product and this manual 

without notice.

• Warning regarding the use designated and the use 

limitations of the product.

This  product  is  an  transmitter  radio  indicated 

for  the  audio  broadcasting  service  in  frequency 

modulation.  It  uses  working  frequencies  that  are  not 

harmonized in the states of designated user. 

 

The  user  of  this  product  must  obtain  from  the Authority 

for  spectrum  management  in  the  state  of  designated 

user  the  appropriate  authorization  to  use  the  radio 

spectrum, before putting in exercise this equipment.   

The  working  frequency,  the  transmitter  power,  let  alone 

other specifications of the transmission system are subject 

to limitation and definited in the authorization obtained.

 

2.  Warranty

R.V.R.  Electronics  S.P.A. 

guarantees  absence  of 

manufacturing  defect  and  the  good  operation  for  the 

products, within the provided terms and conditions.
Please read the terms carefully, because the purchase of 

the product or acceptance of order confirmation, constitutes 

acceptance of the terms and conditions.
For the last legal terms and conditions, please visit our web 

site (WWW.RVR.IT) wich may also be changed, removed 

or updated for any reason without prior notice.
Warranty will be void in cases of opened products, physical 

damage,  misuse,  modification,  repair  by  unauthorised 

persons,  carelessness  and  using  the  product  for  other 

purpose than its intended use.
In case of defect, proceed like described in the following:
1  Contact the dealer or distributor where you purchased 

the unit. Describe the problem and, so that a possible 

easy solution can be detected.

Dealers and Distributors are supplied with all the information 

about problems that may occur and usually they can repair 

the unit quicker than what the manufacturer could do. Very 

often installing errors are discovered by dealers.
2  If your dealer cannot help you, contact  

R.V.R. Elettronica

 

and explain the problem. If it is decided to return the 

unit to the factory,  

R.V.R. Elettronica

  will mail you a 

regular authorization with all the necessary instructions 

to send back the goods;

3  When you receive the authorization, you can return the 

unit. Pack it carefully for the shipment, preferably using 

the  original  packing  and  seal  the  package  perfectly. 

The customer always assumes the risks of loss (i.e., 

IMPORTANT

The symbol of lightning inside a triangle placed on the product, evidences the operations for 

which is necessary gave it full attention to avoid risk of electric shocks. 

The symbol of exclamation mark inside a triangle placed on the product, informs the user 

about the presence of instructions inside the manual that accompanies the equipment, im-

portant for the efficacy and the maintenance (repairs).

Summary of Contents for GPSRXNV-01

Page 1: ...GPSRXNV 01 User Manual Volume 1 Manufactured by Italy ...

Page 2: ...rm or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner Name File 03_GPSRXNV 01_ING_1 0 indd Version 1 0 Date 16 11 2007 Revision History Date Version Reason Editor 16 11 2007 1 0 First Edition J H Berti Declaration of Conformity Hereby R V R Elettronica SpA declares that this F...

Page 3: ...Quick guide for installation and use 4 5 1 Preparation 4 6 External Description 8 6 1 Frontal Panel 8 6 2 Rear Panel 8 6 3 Connectors description 9 7 Technical Specifications 10 7 1 Mechanical Specifications 10 7 2 Electrical Specifications 10 7 3 Spare Parts 10 8 Module identification 12 8 1 Top View 12 9 Working Principles 13 9 1 Power supply card PSS1201 01 13 9 2 Interface card SL041IN1001 13 ...

Page 4: ...GPSRXNV 01 ii User Manual Rev 1 0 16 11 07 This page was intentionally left blank ...

Page 5: ... measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a commitment by R V R Elettronica SpA The R V R Elettronica SpA assumes no responsability or liability for any errors or inaccuracies that may appear in this manual including the products and software described in ...

Page 6: ...sent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuers the rythm shall be of one brath each 5 compressions Do not interrupt the rythm of compressions when the second person is giving breath Call for medical assistance as soon as possible 3 1 2 If victim is resp...

Page 7: ...XNV 01 is compact design and user friendliness Another key feature is its modular concept design the different functions are performed by modules with most connections achieved through male and female connectors or through flat cables terminated by connectors This design facilitates maintenance and module replacement The GPSRXNV 01 contains a buffer battery to avoid possible lack of power supply a...

Page 8: ...ections with detailed descriptions of all hardware and firmware features and capabilities Please see the relevant sections for additional details The topics covered in this section are discussed at greater length in the next sections with detailed descriptions of all hardware and firmware features and capabilities Please see the relevant sections for additional details 5 1 Preparation 5 1 1 Prelim...

Page 9: ...his condition and set the switch to ON BATTERY position see figure 6 2 note 11 after powering the system 5 1 3 Connections Connect tge GPS ANTENNA input of GPSRXNV 01 see figure 6 2 note 11 to antenna receiver figure 5 1 Figure 5 1 Connect the 10MHz OUT 1 output of GPSRXNV 01 figure 6 1 note 4 to the proper IN 10MHZ input equipped with apparatus of R V R Elettronica like PTX LCD with SFN option fi...

Page 10: ...again when the phase locking of 10MHz e 1PPS signal happens the EBO OK will be again light on too In case that you made explicit request for purchase the software license of EPSILON BOARD OEM II card at time of order the reading parameters of GPSRXNV 01 and of satellites will be made through the serial connection between the RS232 and the DB9 placed in front panel and a compatible PC with Microsof...

Page 11: ... 14 User Manual Rev 1 0 16 11 07 GPSRXNV 01 Figura 5 3 ...

Page 12: ...S DB9 M connector for the alarm output status of the equipment through the contacts available 4 10MHz OUT 1 BNC connector for the signal output at 10MHz for the synchronism of the carrier 5 10MHz OUT 2 BNC connector for the auxiliary signal output at 10MHz for the synchronism of the carrier only in case of presence of proper option 6 10MHz OUT 3 BNC connector for the auxiliary signal output at 10M...

Page 13: ...41IN1001 is in pos 2 3 or 3 4 12V signalling in case of normal operation condition If JP6 SL041IN1001 is in pos 1 2 12V signalling in case of alarm If JP6 SL041IN1001 is in pos 4 5 12V always active 5 GND GND 6 EBO OK OUT dig Closed contact if PIN7 is in normal operating condition 7 EBO OK OUT dig Common contact 8 EBO OK OUT dig Closed contact if PIN7 is in alarm condition 9 EBO OK OUT an Tip JP5 ...

Page 14: ...ply 12VDC Accuracy to UTC with GPS locked 50 ns 1σ 10MHz output frequency accuracy 2 x 10 12 GPS system Integrated Antenna Input Connector N type Uscita 5V output for antenna power supply 1pps TTL output Connector BNC Typical level TTL 10MHz output Connector BNC Signal Form sinusoidal Typical level 5 dBm 50Ω Harmonic Distortion 25 dBc Connectors RS232 serial interface DB9 female connector to conne...

Page 15: ...7 3 Spare Parts Subsets for Maintenance Panel board SL041PC1001 Interface card and battery charger SL041IN1001 Power supply card PSS1201 01 Parts of parts Transformer TRFALT0001 GPS receiver EPSILON BOARD OEM II Buffery battery 12V 2Ah BATTPG12V2A2 ...

Page 16: ...onnectors to facilitate maintenance and replacement if needed 8 1 Top View The figure 8 1 shows a top view of the equipment and component locations Figure 8 1 1 Panel Board SL041PC1001 2 Buffer battery BATTPG12V2A2 3 Transformer TRFALT0001 4 Power supply card PSS1201 01 5 Interface card SL041IN1001 6 GPS receiver EPSILON BOARD OEM II ...

Page 17: ... supply of analog section and a voltage of 7 V for the power supply of digital logic section In case of absence of network and in case the switch on the rear panel of the battery is enabled the equipment automatically switches the power supply on the internal buffer battery thus guaranteeing the continuity of the service 9 2 Interface card SL041IN1001 This card performs the following tasksi Interf...

Page 18: ...Panel board SL041PC1001 This card is mounted on the frontal panel The panel board provides the visualization via LEDs related to status of equipment Also hosts the RS232 connector for direct serial communication normally used only for factory settings ...