background image

1 / 8

User Manual

Rev. 1.0 - 06/02/09

IBJECT12K10A & IBJECT12K10B

 

1.  Preliminary Instructions

• General foreword

The  equipment  in  object  is  to  considering  for  uses, 

installation  and  maintenance  from  “trained”  or  “qualified” 

staff,  they  conscious  of  the  risks  connected  to  operate 

on electronic and electrical circuits electrical.   

 

The  “trained”  definition  means  staff  with  technical 

knowledge  about  the  use  of  the  equipment  and  with 

responsibility  regarding  the  own  safety  and  the  other 

not  qualified  staff  safety  place  under  his  directed 

surveillance in case of works on the equipment.   

 

The “qualified” definition means staff with instruction and 

experience  about  the  use  of  the  equipment  and  with 

responsibility regarding the own safety and the other not 

qualified staff safety place under his directed surveillance 

in case of works on the equipment. 

  WARNING:  The  machine  can  be  equipped  with 

an ON/OFF switch which could not remove completely 

voltages  inside  the  machine.  It  is  necessary  to 

have  disconnected  the  feeding  cord,  or  to  have 

switched  off  the  control  panel,  before  to  execute 

technical  operations,  making  sure  himself  that  the 

safety connection to ground is connected. 

 

The technical interventions that expect the equipment 

inspection with circuits under voltage must be carry out 

from trained and  

qualified  staff  in  presence  of  a 

second  trained  person  that  it  is  ready  to  intervene 

removing voltage in case of need.
R.V.R. Elettronica SpA

 doesn’t assume responsibility for 

injury  or  damage  resulting  from  improper  procedures  or 

practices by untrained/unqualified personnel in the handling 

of this unit.

 WARNING: The equipment is not water resistant 

and  an  infiltration  could  seriously  compromise 

its  correct  operation.    In  order  to  prevent  fires  or 

electric shocks, do not expose the equipment to rain, 

infiltrations or humidity.

Please observe all local codes and fire protection standards 

during installation and use of this unit.

  WARNING:  The  equipment  has  to  its  inside 

exposed  parts  to  risk  of  electric  shock,  always 

disconnect power before opening covers or removing 

any part of this unit.

Fissures and holes are supplied for the ventilation in order 

to assure a reliable efficacy of the product that for protect 

itself from excessive heating, these fissures do not have 

to be obstructed or to be covered. The fissures doesn’t be 

obstructed in no case.  The product must not be incorporated 

in a rack, unless it is supplied with a suitable ventilation or 

that the manufacturer’s instructions are been followed.

  WIRING:  This  equipment  can  irradiate  radio 

frequency  energyand  if  it’s  not  installed  following 

the  instructions  contained  in  the  manual  and  local 

regulations  it  could  generate  interferences  in  radio 

communications.

 WIRING: This device has a connection to ground 

on the power cord and on the chassis.  Check that they 

are correctly connected.

Operate with this device in a residential ambient can cause 

radio disturbs; in this case, it can be demanded to the user 

to take adequate measures.

Specifications and informations contained in this manual  

are furnished for information only, and are subject to change 

at  any  time  without  notice,  and  should  not  be  construed 

as a commitment by 

R.V.R. Elettronica SpA

 

The 

R.V.R. Elettronica SpA

 assumes no responsability or 

liability for any errors or inaccuracies that may appear in 

this manual, including the products and software described 

in it;and it reserves the right to modify the design and/or 

the technical specifications of the product and this manual 

without notice.

• Warning regarding the use designated and the use 

limitations of the product.

This  product  is  an  transmitter  radio  indicated 

for  the  audio  broadcasting  service  in  frequency 

modulation.  It  uses  working  frequencies  that  are  not 

harmonized in the states of designated user. 

 

The  user  of  this  product  must  obtain  from  the Authority 

for  spectrum  management  in  the  state  of  designated 

user  the  appropriate  authorization  to  use  the  radio 

spectrum, before putting in exercise this equipment.   

The  working  frequency,  the  transmitter  power,  let  alone 

other specifications of the transmission system are subject 

to limitation and definited in the authorization obtained.

 

2.  Warranty

R.V.R.  Electronics  S.P.A. 

guarantees  absence  of 

manufacturing  defect  and  the  good  operation  for  the 

products, within the provided terms and conditions.
Please read the terms carefully, because the purchase of 

the product or acceptance of order confirmation, constitutes 

acceptance of the terms and conditions.
For the last legal terms and conditions, please visit our web 

site (WWW.RVR.IT) wich may also be changed, removed 

or updated for any reason without prior notice.
Warranty will be void in cases of opened products, physical 

damage,  misuse,  modification,  repair  by  unauthorised 

persons,  carelessness  and  using  the  product  for  other 

purpose than its intended use.
In case of defect, proceed like described in the following:
1  Contact the dealer or distributor where you purchased 

the unit. Describe the problem and, so that a possible 

easy solution can be detected.

Dealers and Distributors are supplied with all the information 

about problems that may occur and usually they can repair 

the unit quicker than what the manufacturer could do. Very 

often installing errors are discovered by dealers.
2  If your dealer cannot help you, contact  

R.V.R. Elettronica

 

and explain the problem. If it is decided to return the 

unit to the factory,  

R.V.R. Elettronica

  will mail you a 

regular authorization with all the necessary instructions 

to send back the goods;

3  When you receive the authorization, you can return the 

unit. Pack it carefully for the shipment, preferably using 

the  original  packing  and  seal  the  package  perfectly. 

The customer always assumes the risks of loss (i.e., 

IMPORTANT

The symbol of lightning inside a triangle placed on the product, evidences the operations for 

which is necessary gave it full attention to avoid risk of electric shocks. 

The symbol of exclamation mark inside a triangle placed on the product, informs the user 

about the presence of instructions inside the manual that accompanies the equipment, im-

portant for the efficacy and the maintenance (repairs).

Summary of Contents for IBJECT12K10A

Page 1: ...User Manual Manufactured by Italy IBJECT12K10A IBJECT12K10B...

Page 2: ...any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner HD Radio Technolo...

Page 3: ...nstructions 1 2 Warranty 1 3 First Aid 2 3 1 Treatment of electrical shocks 2 3 2 Treatment of electrical Burns 2 4 Unpacking 3 4 1 General Description 3 5 Installation and configuration procedure 4 5...

Page 4: ...IBJECT12K10A IBJECT12K10B ii User Manual Rev 1 0 06 02 09 This page was intentionally left blank...

Page 5: ...equate measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a commit...

Page 6: ...is absent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuers...

Page 7: ...cription The IBJECT12K10A and IBJECT12K10B henceforth to commonly named IBJECT12K10 manufactured by R V R Elettronica SpA are injectors able to mix a digital signal maximum power 2 5 kW to an existing...

Page 8: ...lied with the equipment ready at hand throughout the whole procedure the Final Test Table lists all operating parameters as set and tested at the factory 5 1 Preparation 5 1 1 Preliminary checks Unpac...

Page 9: ...SMITTING SOURCE ANALOG DIGITAL COMBINER INJECTOR HD RADIO SIGNAL GENERATOR DUMMY LOAD HD RADIO DRIVER AMPLIFIER DJ50 DJ1000 TDX IBOC001 IBJECT12K10 E2X LINK EXPORTER Figure 5 1 High level mixed signal...

Page 10: ...N RF input connector for analog FM source 1 5 8 type 2 REJECTED OUT RF ouput connector of rejected power for dummy load 7 16 DIN type IBJECT12K10A version or 7 8 EIA type IBJECT12K10B version 3 DIGITA...

Page 11: ...gital Weight kg About 7 kg About 7 kg Ambient working temperature C 50 to 70 50 to 70 Whithout condensing Isolation dB At least 38 At least 38 Coupling dB 10 10 Return Loss dB At least 26 At least 26...

Page 12: ...8 User Manual Rev 1 0 06 02 09 IBJECT12K10A IBJECT12K10B This page was intentionally left blank...

Reviews: