2 / 8

User Manual

Rev. 1.0 - 06/02/09

IBJECT12K10A & IBJECT12K10B

R.V.R. is never responsible for damage or loss), until 

the package reaches R.V.R. premises. For this reason, 

we suggest you to insure the goods for the whole value. 

Shipment  must  be  effected  C.I.F.  (PREPAID)  to  the 

address specified by R.V.R.’s service manager on the 

authorization

 

DO  NOT  RETURN  UNITS  WITHOUT  OUR 

AUTHORIZATION AS THEY WILL BE REFUSED

4  Be  sure  to  enclose  a  written  technical  report  where 

mention  all  the  problems  found  and  a  copy  of  your 

original  invoice  establishing  the  starting  date  of  the 

warranty.

Replacement  and  warranty  parts  may  be  ordered  from 

the  following  address.  Be  sure  to  include  the  equipment 

model and serial number as well as part description and 

part number.

 

R.V.R. Elettronica SpA 

Via del Fonditore, 2/2c 

40138 BOLOGNA ITALY 

Tel. +39 051 6010506

 

3.  First Aid

The  personnel  employed  in  the  installation,  use  and 

maintenance of the device, shall be familiar with theory and 

practice of first aid.

 

3.1  Treatment of electrical shocks

 

3.1.1  If the victim is not responsive

Follow the A-B-C’s of basic life support.

• 

Place  victim  flat  on  his  backon  a  hard 

surface.

• 

Open airway: lift up neck, push forehead back 
(

Figure 1

). 

Figure 1

• 

clear out mouth if necessary and observe for 

breathing

• 

if  not  breathing,  begin  artificial  breathing  

(

Figure 2

): tilt head, pinch nostrils, make airtight 

seal, four quick full breaths. Remember mouth 

to mouth resuscitation must be commenced as 

soon as possible.

Figure 2

• 

Check  carotid  pulse  (

Figure  3

);  if  pulse  is 

absent,  begin  artificial  circulation  (

Figure  4

depressing sternum (

Figure 5

).

           

      Figure 3

                    

Figure 4

Figure 5

• 

In case of only one rescuer, 15 compressions 

alternated to two breaths.

• 

If there are two rescuers, the rythm shall be of 

one brath each 5 compressions. 

• 

Do  not  interrupt  the  rythm  of  compressions 

when the second person is giving breath.

• 

Call for medical assistance as soon as  

possible.

 

3.1.2  If victim is responsive

• 

Keep them warm.

• 

Keep them as quiet as possible.

• 

Loosen  their  clothing (a  reclining  position  is 

recommended).

• 

Call for medical help as soon as possible.

 

3.2  Treatment of electrical Burns

 

3.2.1  Extensive burned and broken skin

• 

Cover  area  with  clean sheet or cloth.

• 

Do not break blisters, remove tissue, remove 

adhered particles of clothing, or apply any salve 

or ointment.

• 

Treat victim for shock as required.

• 

Arrange transportation to a hospital as quickly 

as possible.

• 

If  arms  or  legs  are  affected  keep  them 

elevated.

If  medical  help  will  not  be  available  within  an  hour  and 

the victim is conscious and not vomiting, give him a weak 

solution of salt and soda: 1 level teaspoonful of salt and 

1/2 level teaspoonful of baking soda to each quart of water 

(neither hot or cold).

Allow victim to sip slowly about 4 ounces (half a glass) over 

a period of 15 minutes. 

Discontinue fluid if vomiting occurs.

DO NOT give alcohol.

  3.2.2  Less severe burns

• 

Apply cool (not ice cold) compresses using the 

cleansed available cloth article.

• 

Do not break blisters, remove tissue, remove 

adhered particles of clothing, or apply salve or 

ointment.

• 

Apply clean dry dressing if necessary.

• 

Treat victim for shock as required.

• 

Arrange transportation to a hospital as quickly 

as possible.

• 

If  arms  or  legs  are  affected  keep  them 

elevated.

Summary of Contents for IBJECT12K10A

Page 1: ...User Manual Manufactured by Italy IBJECT12K10A IBJECT12K10B...

Page 2: ...any form or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner HD Radio Technolo...

Page 3: ...nstructions 1 2 Warranty 1 3 First Aid 2 3 1 Treatment of electrical shocks 2 3 2 Treatment of electrical Burns 2 4 Unpacking 3 4 1 General Description 3 5 Installation and configuration procedure 4 5...

Page 4: ...IBJECT12K10A IBJECT12K10B ii User Manual Rev 1 0 06 02 09 This page was intentionally left blank...

Page 5: ...equate measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a commit...

Page 6: ...is absent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuers...

Page 7: ...cription The IBJECT12K10A and IBJECT12K10B henceforth to commonly named IBJECT12K10 manufactured by R V R Elettronica SpA are injectors able to mix a digital signal maximum power 2 5 kW to an existing...

Page 8: ...lied with the equipment ready at hand throughout the whole procedure the Final Test Table lists all operating parameters as set and tested at the factory 5 1 Preparation 5 1 1 Preliminary checks Unpac...

Page 9: ...SMITTING SOURCE ANALOG DIGITAL COMBINER INJECTOR HD RADIO SIGNAL GENERATOR DUMMY LOAD HD RADIO DRIVER AMPLIFIER DJ50 DJ1000 TDX IBOC001 IBJECT12K10 E2X LINK EXPORTER Figure 5 1 High level mixed signal...

Page 10: ...N RF input connector for analog FM source 1 5 8 type 2 REJECTED OUT RF ouput connector of rejected power for dummy load 7 16 DIN type IBJECT12K10A version or 7 8 EIA type IBJECT12K10B version 3 DIGITA...

Page 11: ...gital Weight kg About 7 kg About 7 kg Ambient working temperature C 50 to 70 50 to 70 Whithout condensing Isolation dB At least 38 At least 38 Coupling dB 10 10 Return Loss dB At least 26 At least 26...

Page 12: ...8 User Manual Rev 1 0 06 02 09 IBJECT12K10A IBJECT12K10B This page was intentionally left blank...

Reviews: