PJ300M
23 / 28
User Manual
Rev. 7.0 - 25/07/03
•
Disconnect the RF module connectors CN1, J1 and J2
•
Remove the air filter of the RF module from the front panel
•
Unscrew two screws securing the heat sink of the RF module to the front panel
•
Release the metal bar that holds the heatsink on the other end removing its screws
•
Carefully remove the amplifier module
9.3.4
Soft Start Card Replacement
•
With the help of the wiring diagram shown in Appendix, take the note of the
cable position.
•
Disconnect M1 and M2 connectors.
•
Disconnect M3.
•
Dismount the four securing screws and remove the board.
9.3.5
Alarms Card Replacement
•
Remove the knob of the meter selector loosening the screw inside the knob.
•
Dismount the nut of the alarms reset push-button.
•
Disconnect CN1 and CN3 alarms card’s connectors.
•
Disconnect CN2 telemetry card’s connector.
•
Remove the screws securing the board to the front panel.
•
Carefully extract the card.
Summary of Contents for PJ300M
Page 1: ...Manufactured by Italy PJ300M User Manual Volume 1...
Page 4: ...This page intentionally left blank...
Page 6: ...PJ300M ii User Manual Rev 7 0 25 07 03 This page was intentionally left blank...
Page 8: ...PJ300M 2 28 User Manual Rev 7 0 25 07 03 This page was intentionally left blank...
Page 14: ...PJ300M 8 28 User Manual Rev 7 0 25 07 03 This page was intentionally left blank...
Page 18: ...PJ300M 12 28 User Manual Rev 7 0 25 07 03 This page was intentionally left blank...
Page 22: ...PJ300M 16 28 User Manual Rev 7 0 25 07 03 This page was intentionally left blank...
Page 24: ...PJ300M 18 28 User Manual Rev 7 0 25 07 03 This page was intentionally left blank...
Page 30: ...PJ300M 24 28 User Manual Rev 7 0 25 07 03 This page was intentionally left blank...