14
/ 24
Manuale Utente
Rev. 1.0 - 20/02/12
RDMODWEB
ELETTRONICA
% Power Out
Shows power setting efficiency.
Foldback
Shows the triggered status of the foldback function (automatic reduction
of output power).
Ext R.F. Mute
Shows the status of power inhibition by an interlock signal.
Unlock
Shows the status of lock at frequency set by PLL.
5.3.3 Device Setting Menu
Nota :
L’accesso a questo menù, ed eventuale modifica dei parametri, è possibile
solo se si è effettuato il login come amministratore.
This page not only shows the user the information about the exciter connected to
the
RDMODWEB
interface, but also allows setting various parameters.
Following is a description of the items that allow modification of the parameter,
with respect to the
Status
menu (chapt. 5.3.2). Press the
Update
button to confirm
selection; if you let timer to time out or press the
RVR
logo, the parameter setting
will remain as previously set.
Set Device
Ready...
PowerON
On State
On
Update
Frequency
98 MHz
Update
Modulation
0.4 KHz
Forward Power
300.6 W
Reflected Power
6.8 W
Pa Voltage
50.5 V
PA Current
9 A
Temperature
3.6 C
% Power Out
100 %
Update
Foldback
Off State
Ext R.F. Mute
No Mute State
Unlock
Absent State
Menu 6
Power ON
Enables (ON) or disables (OFF) exciter power output.