14 / 34
User Manual
Rev. 1.1 - 07/02/14
TELINK-SNMP2
synchronization from a minimum of 300 to a maximum of 86400 ticks.
Set 0 to disable.
New Server Name
Setting of NTP server to adjust system clock. Write the name of NTP
server in the box that you want to assign, then press the Set Server
button to apply the choice.
5.3.6 Command Menu - Administrator
Note : Access to this menu and modifi cation of these parameters are only possible
after login with administrator rights.
This page not only shows the user the information about the exciter connected to
the TELINK-SNMP2 interface, but also allows setting various parameters.
The upper part allows you to enable or disable the Auto-refresh by clicking on the
relevant
box.
With Auto-refresh enabled the measures are taken every 3 seconds (“Get
Data ..”) and gave available in a legible form by the current page (“Ready”).
With Auto-refresh disabled the measures are frozen (“Stopped”) at the time when
you uncheck the box and gave available in a legible form by the current page.
Following is a description of the items that allow modifi cation of the parameter, with
respect to the Measure menu. Press the buttons to confi rm your choice, if you let
timer to time out, the parameter setting will remain as previously set.
Menu 7
Freq.
Remote adjustment of exciter frequency. This value, in MHz, can be
modifi ed according to one’s own band in 0.1 MHz steps. Press Set to
confi rm the value inserted.
CMD ON
Enables (ON) the exciter power output. Press Set to change the logical
state of the data.