BD-C Series

-7

Laser Displacement Sensor Communication Converter

Features

● Supports RS232C and RS485 communications in one device

: Separated ports of RS232C/RS485 for user convenience

● Maximum connection up to 8 amplifier units
● Power supply without extra wiring via amplifier unit 
● Dedicated Device Management Program (atDisplacement)

: Batch parameter setting via save/load function
: Real-time monitoring of measured values and output status

●  Communication speed and station number can be set by side DIP switch 

without connecting host device

Manual

For the detail information and instructions, please refer to the manual, and be sure to follow cautions written in the technical 

descriptions (catalog, website).

Visit our website (www.autonics.com) to download manuals.

Proper Usage

Before using the communication converter unit, depending on the usage environment, keep following items handy.

Visit our web site(www.autonics.com) to download.
• atDisplacement program, manual

• SCM-38I (RS232C - RS485) Driver, Instruction manual

• SCM-US48I (USB - RS485) Driver, Instruction manual

• SCM-WF48 (Wi-Fi, USB - RS485) Driver, Instruction manual

• BD Series manual

Dedicated Device Management Program (atDisplacement)

• atDisplacement is BD-C Series management program for convenient management of multiple device data monitoring.

• Visit our website (www.autonics.com) to download user manual and program.

◎ System requirement

Item

Minimum requirements

System 

IBM PC compatible computer with 1GHz + processor

Operations

Microsoft Windows 7 +

Memory

2GB + 

Hard disk

1GB + of available hard disk space 

VGA

Resolution: 1920×1080 or higher

Others

RS-232 serial port (9-pin), USB port

Please read “Safety Considerations” 

in the instruction manual before using.

Summary of Contents for BD-C Series

Page 1: ...load manuals Proper Usage Before using the communication converter unit depending on the usage environment keep following items handy Visit our web site www autonics com to download atDisplacement program manual SCM 38I RS232C RS485 Driver Instruction manual SCM US48I USB RS485 Driver Instruction manual SCM WF48 Wi Fi USB RS485 Driver Instruction manual BD Series manual Dedicated Device Management...

Page 2: ... weight The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment BD C Series Communication Converter Model BD CRS Power supply 1 Power consumption Max 2 3W Communication function RS 232C RS 485 Communication speed 9600 19200 38400 115200bps default Indication 4 LED status indicators Function Real time monitoring Executes every BD Series feature and ...

Page 3: ...ly Communication output indicator TX Green Displays communication output status from communication converter to external device Communication input indicator RX Green Displays communication input status from communication converter to external device Communication error indicator ERROR Red Displays the communication status of communication converter 4 Communication Setting Switch Sets communicatio...

Page 4: ...SUB 9 pin cable 1 6 2 3 4 5 7 8 9 1 6 2 3 4 5 7 8 9 RS485 communication Pin Name Description 1 A RS485 signal 2 B RS485 signal Communication pin Terminating switch Set the switch to RT when the communication converter is connected to the terminal of RS485 communication connection and set to OFF when it is in the middle of the communication connection 1 A B 2 Application of system organization Comp...

Page 5: ...ommunication converter It is calculated in binary according to the ON OFF status of each switch Switch No Switch3 Switch4 Switch5 Switch6 Switch7 Address Binary digit OFF 0 ON 1 2 4 2 3 2 2 2 1 2 0 Address Switch 3 2 4 Switch 4 2 3 Switch 5 2 2 Switch 6 2 1 Switch 7 2 0 1 Address 1 OFF OFF OFF OFF OFF 1 0 2 4 0 2 3 0 2 2 0 2 1 0 2 0 1 Address 2 OFF OFF OFF OFF ON 2 0 2 4 0 2 3 0 2 2 0 2 1 1 2 0 1 ...

Page 6: ...necting amplifier unit Mount on DIN rail Do not supply the power when adding amplifier unit Supply power to each connected amplifier unit at the same time Up to 8 amplifier units can be connected and only 1 calculation function can be performed per 1 group of mutually connected amplifiers When the calculation function is activated the setting values SV of the slave units are disable and the mutual...

Page 7: ...TX Green Displays communication output status from communication converter to external device Status Reason Solution Flashing Signal is outputting Off Signal is not outputting Communication input indicator RX Green Displays communication input status from communication converter to external device Status Reason Solution Flashing Signal is inputting Off Signal is not inputting Communication error i...

Reviews: