background image

STEALTH-IN-1114

1. 

Attach the Universal Mounting bar with the screws provided to the junc-

tion box. If you are attaching your STL360 kit to a surface mount weath-

erproof box, you must use with the metal mouting plate with gasket. 

2. 

Easy Wiring Tip:

 

Use the “S” shaped Hands  

Free Hanging Hook to hold  

the CU4 EZ Plate during wiring. 

3. 

Bring power leads and sensor  

kit leads through holes in  

gasket and plate into  

junction box. 

4. 

Strip 1/2” of insulation from 

all leads. 

5. 

Attach ground wire(s) to junction box grounding screw.  

Connect as shown in wiring diagram on page 7. 

6. 

Twist on wire nuts. Secure with electrical tape. 

7. 

Align CU4 EZ Plate and metal surface plate with gasket (for use with 

surface mounted junction boxes) to ensure proper seal. Tighten CU4 EZ 

Plate center screw (make sure O-Ring gasket is on the screw) to attach 

CU4 EZ Plate to the box. 

8. 

Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath-

erproof seal. 

9. 

Use silicone sealant around plate and all opening to ensure a weather 

proof seal.  Seal all unsued conduit entries on surface junction box. 

10. 

Screw in light bulbs. Turn on power. Conduct walk test to adjust  

sensor response (see page 15).

STL360HBW

STL360H

Insert 

close-up

plug in 

unused 

hole

Finishing 

Cap

Bar Screws

Gasket &

Surface Plate

Universal

Mounting

Bar

Hook

O-Ring

Gasket

CU4 EZ Plate

Gasket

Center

Screw

Black

Black

Red

   Red 

(pigtail)

Ground

Ground

Power In

White

White

Mounting

STL360 Kit Assembly and Wiring

STL360 floodlight kits come pre-wired and assemble on the RAB CU4 EZ 

plate, allowing for mounting on round, rectangular or octagonal surface or 

recessed boxes.

Wiring

Red pigtail is only used to switch 

remote or additional fixtures.

Hood rests 

in notch on 

crossbar

Hands Free 

Hanging 

Hook

CU4 EZ Plate

7

8

Summary of Contents for FFLED18

Page 1: ...or silicone sealant 2 Secure the LED Flood to a 1 2 NPS hole in a junction box or landscape post 3 Plug all unused holes and seal threads with silicone 4 The swivel arm on the LED Flood allows 140 150...

Page 2: ...e at the fixture is correct Refer to wiring directions 2 Is the fixture grounded properly 3 Is the photocell if used functioning properly Note These instructions do not cover all details or variations...

Page 3: ...volts Cautions TURN OFF ALL POWER AT CIRCUIT BREAKER FUSE PANEL Read entire Installation Manual before proceeding All wiring should comply with local electrical codes and requires a qualified electri...

Page 4: ...es Since the lights are on only when needed and the sensor uses only one watt The Stealth is extremely energy efficient Can outdoor lights still be turned on with the light switch Yes STL360 can be co...

Page 5: ...st be located below and as far away as possible from its lights The best location is where the sensor can see all paths of movement The sensor may be wall or soffit mounted As distance from the sensor...

Page 6: ...f the detection zone may be high in the air over people s heads Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern move quickly Check that move ment far awa...

Page 7: ...ure O Ring gasket is on the screw to attach CU4 EZ Plate to the box 8 Insert plastic Finishing Cap in the center of the CU4 EZ Plate for a weath erproof seal 9 Use silicone sealant around plate and al...

Page 8: ...shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in CU4 EZ Plate are closed with plugs provided 11 Use silicone sealant around plate and all o...

Page 9: ...nd then off at bedtime To activate the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on off on off on within 3 seconds If you activate the EVENING TIMER during dayti...

Page 10: ...keep lights on for 5 seconds each time it detects movement in its detection zone Perform the walk test and make any adjustments needed Vacate the detection zone for one minunte to end Test Mode Scann...

Page 11: ...is not triggering sensor Make sure the sensor is below and as far as possible away from lights Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northv...

Page 12: ...ops 8 Moths can be attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under Lights Do Not Turn OFF 1 Check that...

Page 13: ...itive Less sensitive TIME 1 8 HRS 5 SECS 12 MINS EVENING TIMER SENS Technical Tips Lights Turn Off too quickly WRONG OK Technical Tips Range Appears Limited 1 Check that the sensor is level from side...

Page 14: ...r who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrician or under the supervision of a...

Reviews: