background image

19724 MICROWAVE SENSOR FOR D10

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com

TROUBLESHOOTING

If the sensor does not detect motion as expected: 

•  Check fixture mounting to compare fixture location and 

sensor coverage with the coverage diagrams on pg 2

•  Adjust fixture location as necessary

Fixture will not light/sensor does not detect motion: 

•  Make sure ON/OFF button was not selected as this 

results in disabling the sensor

•  Check all settings to be sure there is no conflicting 

selection with the ambient light level

Fixture and sensor are too active: 

•  Check detection area setting and reduce coverage as 

needed

•  Increase time delay and/or adjust cut off period.

Basic Function Overview:

REMOTE CONTINUED

 

Detection Range Button Group: 

assigns detection range of 

10, 50 or 100%; 

use coverage diagrams on pg 2 for guidance. 

To limit area in which motion will set off sensor, use a smaller 

percent. The sensor will not detect motion outside of 100% 

and the fixture will not light.

Time Delay Button Group: 

assigns hold time of 30 seconds, 

1 minute, 5 minutes, 10 minutes, or 30 minutes

Cut Off Button Group: 

assigns cut off period of 0 seconds, 

10 seconds, 1 minute, 10 minutes, 30 minutes, or 1 hour. 0 

seconds gives fixture on/off control rather than dimming. 

+ ∞ keeps the light on always (if daylight sensor is disabled) 

with Bi-Level dimming control.

 

Dim Level:

 assigns level of 10, 20, or 30% for dimmed light 

output after time delay passes

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance.

Easy Installation & Product Help

Tech Help Line

Call our experts 888 RAB-1000

©2016 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

rabweb.com

Visit our website for product info

email

Answered promptly sales@rabweb.com

19724 IN 0616

REMOTE

Sensor will beep one time 

to indicate remote recieved 

signal successfully
Remote settings will override 

DIP Switch settings

ON/OFF:

 disables sensor;  

light is permanently* on or off

*un-do permanent on/off by  
selecting either Auto-Mode, RESET, 
or any Scene mode button

Auto Mode:

 sensor activates 

and all previously selected 

settings remain programmed

RESET: 

overrides selected  

settings; reverts to DIP  

settings

Dim buttons:

 + dims up and  

- dims down, adjusting lamp 

brightness

Black Button:

 no function

Test 2s: 

automatic* test mode with 2 second time delay;  

disables cut off period and daylight sensor

*un-do automatic test mode by selecting either RESET, any Scene mode  
button, or hold time

Power 100% & Power 80%:

 

adjusts power output; to save  

energy select Power 80%. Must return to full output after initial 

10,000 hours of LEDs by pressing Power 100%.

Group B:

Yellow Sun Button: 

Ambient Daylight Threshold;  

records surrounding lux level and overwrites previously  

recorded value

.2, 1 and 5 fc:

 sets daylight sensor at respective ambient light 

values

Disable: 

disables daylight sensor; any motion  

registered by sensor activates fixture light

SC1, SC2, SC3, SC4:

 assigns one of 4 pre-set scenes; see  

“Operation” on pg 2 for scene descriptions

Fig. 5

100%

Re

du

ce

d L

ev

el

Occupied

Time Delay

Cut Off

G

roup B

Fig. 6

Summary of Contents for HALV

Page 1: ...s the following protocols Triac and ELV at 120V ONLY For 0 10V dimming connect purple wire to the V DIM lead and the grey wire to the V DIM lead This fixture is damp listed and suitable for indoor applications on walls Driver is 120V 277V and 50Hz or 60 Hz HALV Mounting the fixture on a standard 4 x 4 J BOX This fixture is damp listed and suitable for indoor applications on walls 1 Loosen the 4 dr...

Page 2: ... to box Wall box is installed after sheetrock 1 Remove Driver LED Wall plate assembly by loosening 4 phillips head screws as shown in Figure 1 No need to completely remove screws keyhole slots provided Retain Hanger Unplug connectors if E2 E2 MVS E2 E2 BL or LC E2 and put Driver LED Wall plate aside 2 Discard Nailer Bars 3 Move Stop Brackets from end to side and add Sheetrock Clamps as shown in Fi...

Page 3: ...e over the Driver LED assembly with the phillips head mounting screw at the top See Figure 5 2 Inset the lens frame from the bottom with the bottom flush against the wall See Figure 5 3 Tilt the top of the lens frame to the wall 4 Make sure the frame is flush against the wall and tighten mounting screw at the top using a 5 64 hex key LENS FRAME INSTALLATION Driver LED Assembly DO NOT TOUCH LEDs Mo...

Page 4: ...t at 888 RAB 1000 or email marketing rablighting com Easy Answers rablighting com Visit our website for product info Tech Help Line Call our experts 888 722 1000 e mail Answered promptly sales rablighting com Free Lighting Layouts Answered online or by request 2019 RAB LIGHTING Inc Northvale New Jersey 07647 USA DIMENSIONAL DRAWINGS LENS FRAME ASSEMBLY MODELS WITH BACK BOX LENS FRAME ASSEMBLY STAN...

Page 5: ......

Page 6: ...rred to as R for right position and L for left position when looking at sensor in orientation shown in Fig 2 in which all switches are R See Fig 1 and 2 for each setting s corresponding switches Setting options for each category are noted in parenthesis below Factory Settings designated in bold for each category Detection Area Time Delay how long lamp remains on at 100 after last recognized motion...

Page 7: ... Green LED on antenna will flash slowly for 5 seconds and fixture will blink twice if done correctly Surrounding fc will be measured and recorded for 1 second Green LED on antenna and fixture will light for 10 sec onds to indicate successful fc recording Most recent fc measurement overwrites any prior DIP settings pg 1 and ambient lux overwrite eachother depending on latest action Scene Mode 100 d...

Page 8: ...or 30 for dimmed light output after time delay passes Note These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance Easy Installation Product Help Tech Help Line Call our experts 888 RAB 1000 2016 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info e...

Reviews: