background image

INSTRUCTIONS

FIELD-ADJUSTABLE TOMO™ INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

1. 

Secure 

Surface Mounting Plate

 to Junction Box 

(by 

others)

(Additional attachment to the ceiling may be 

needed for longer fi xtures ).

8ft 

TOMO

 includes a 2nd 

Surface Mounting Plate

 and 

Surface Mount Adaptor 

Plate 

for optional use

 (see Fig. 2)

.

2.  Remove 

End Caps

 as shown in Fig. 1. Separate the 

Housing Cover

 from the 

Lens and Tray Assembly

 by 

sliding the 

Housing Cover

 to the right to unlock from 

Key 

Slots 

as shown in Fig. 3

Pre-installed 

Tether Cables

(2)

 will 

prevent 

Lens and Tray Assembly

 from separating from 

Housing Cover

 as shown in Fig. 1.

3.  Pull supply wires from Junction Box 

(by others)

 through 

center of 

Surface Mounting Plate.

 Use appropriate 

UL rated wire connectors as required by code to make 
electrical splices to fi xture leads.

4.  Align S

urface Mount Adaptor Plate

 to the 

Housing 

Cover

. Using

 (4) 

Screws

(provided)

 secure to the

 Surface 

Mounting Plate.

5. 

Follow appropriate wiring instructions per code.

6.  Push 

Lens and Tray Assembly 

into the 

Housing Cover

Align 

Keys

 into 

Key Slots

 and slide to the left to lock the 

Housing Cover 

into the 

Lens and Tray Assembly

. Snap 

on 

End Caps

.

WARNING: To prevent wiring damage or abrasion, do 

not expose wiring to edges of sharp objects.

TOMO- 2FT

End Cap 

(2)

Surface Mounting Plate

Housing Cover

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding 
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A 
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

WARNING: Make certain power is OFF before installing or maintaining fi xture. No user serviceable parts inside. 

The fi xture is suitable for indoor applications. Suitable for damp locations. Ceiling, Canopy and Pendant mount only.

CEILING MOUNTING

Fig: 1

TOMO- 4FT

TOMO- 8FT

Surface Mount Adaptor Plate

Lens and Tray Assembly

Screws 

(4)

Tether Cable 

(2)

Lens and Tray Assembly

Key Slot

Housing Cover

Surface Mount Adaptor Plate

Fig: 2

Fig: 3

Reviews: