background image

Do NOT discard the filter holder. Discard the old Medium Filter, 

do not reuse.

Every 12 Months

Replacing the BioGS HEPA Filter

Discard the old Activated Carbon Filter, do not reuse.

Always unplug the unit before cleaning/replacing the filters.

Depending on the amount of pollutants in your indoor environment, the life 

span of the filters will vary.

Replacing the Pre-filter

Replacing your Filters

The Pre-Filter is a permanent filter and does not need to be 

replaced. 

1. Pull the tabs on the front of the Pre-Filter to remove it.

2. Put the Pre-Filter to one side while replacing the other filters.

1. Remove the old Medium Filter from the black frame and discard the expired filter.

2. Open new Medium Filter and discard the plastic wrapping. 

3. Secure the new filter in the black frame.

1. Remove old HEPA Filter and discard. 

2. Remove new filter from plastic wrapping. 

3. Place new HEPA Filter in filter case.

1. Remove the old Customized Filter from the black frame and discard expired filter. 

2. Take the new Customized Filter out of the wrapping and place in the black frame. 

3. Make sure the front of the Customized Filter is facing up. See Customized Filter chart,  

    (page 11) , to identify the front of your specific filter.

Do NOT discard the filter holder. Discard the old Customized Filter, 

do not reuse.

Every 12 Months

1. Pull out the old Activated Carbon Filter and discard. 

2. Remove the new Activated Carbon Filter from its      

     plastic wrapping, and place in the filter case.

Return the filters to the filter case in the following order from back to front:

 

-Activated Carbon Filter, 

 

-Customized Filter, 

 

-BioGS HEPA Filter, 

 

-Medium Filter, 

 

-Pre-Filter.

  (See diagram on page 9). 

Filter Cleaning and 

replacement schedule* 

Filters 

Replacement 

Cleaning

Pre-Filter

Customized Filter

Medium 

BioGS

TM

HEPA

Charcoal-based Activated Carbon

Permanent/Washabl

e

Every 12 Months

Every 12 Months 
Every 12 Months

Every 12 Months

*Based on 24/7 operation

permanent filter

Replacing the Medium Filter

Every 12 Months

Every 12 Months

Replacing the Customized Filter 

Replacing the Activated Carbon Filter 

Do NOT discard the Pre-Filter. It is designed to be cleaned and reused.

Discard the old HEPA Filter, do not reuse.

Every Month

Not Required
Not Required
Not Required
Not Required

19

20

See pages 9-12 for detailed instructions

Summary of Contents for MinusA2 SPA-780A

Page 1: ...card now for Product Protection By registering your product and purchase information we can confirm the date of purchase to secure your warranty This confirmation serves as security in the event that...

Page 2: ...plug which means it will fit into a polarized outlet only one way If the plug does not fit into the outlet reverse the plug If it still does not fit contact qualified personnel to install the proper o...

Page 3: ...washable Pre filter When transporting the MinusA2 Air Purifier always hold the handle on the back of the unit Inverter lighting equipment or electronic light fixtures may interfere with remote control...

Page 4: ...anel Mood Light Light Sensor Particle Sensor Air Quality Indicator Battery AAA size Power Mood Light Speed Mode Power Cord Unit Hanger Air Outlet Handle Meet your MinusA2 Front view Back view Remote c...

Page 5: ...ollen Mode is selected the r changes automatically depending on the readings of the air quality sensors The mood light shifts color in the following pattern blue purple light purple pink When this ind...

Page 6: ...pulling 3 Pull the tabs on the front of the Pre Filter to remove it 4 Remove the white Medium Filter from the black frame to discard the plastic wrapping 5 Remove HEPA Filter and discard plastic wrap...

Page 7: ...ver Customized Filter Front color Purple Back color Black Front color Purple Orange Back color Orange Front color Purple Yellow Back color Yellow Front color Black thicker fabric like material Back co...

Page 8: ...nsor detects the brightness of the room If the room is dark the MinusA2 automatically switches to Sleep Mode after three minutes To activate Sleep Mode the unit must be in Auto Mode All other modes of...

Page 9: ...h the Speed and Mode button for three seconds The Air Quality Indicator and Auto Mode Indicator will blink Press the Speed button to choose the sensitivity level Replace Filters Low sensitivity Pollen...

Page 10: ...the Pre Filter washing method 1 Remove the Pre Filter from the unit 2 Fill the sink with lukewarm water and gently wash the Pre Filter under the water for 2 3 minutes or until it is completely clean...

Page 11: ...d place in the black frame 3 Make sure the front of the Customized Filter is facing up See Customized Filter chart page 11 to identify the front of your specific filter Do NOT discard the filter holde...

Page 12: ...and falls outside the scope of responsibil ity of Rabbit Air Please consult a qualified contractor and or specialist supplier to install the mounting bracket Maximum weight of air purifier SPA 780A S...

Page 13: ...tched on the hinges of the main unit Battery could be dead or depleted Remote might not be pointed directly at the unit Make sure the battery is correctly installed Filters may be heavily soiled and d...

Page 14: ...y please contact Rabbit Air at 1 888 866 8862 or by e mail at products rabbitair com 25 26 Limited Warranty Limits and Exclusions First Name____________________________________________________________...

Reviews: