User’s Manual
53
value1
is the first A/D converter channel raw count value
volts1
is the voltage or current corresponding to the first A/D converter channel value (0 to +20 V or
4 to 20 mA)
value2
is the second A/D converter channel raw count value
volts2
is the voltage or current corresponding to the first A/D converter channel value (0 to +20 V or
4 to 20 mA)
RETURN VALUE
0 if successful.
-1 if not able to make calibration constants.
SEE ALSO
anaIn, anaInVolts, anaInmAmps, anaInDiff, anaInCalib, brdInit
Summary of Contents for RabbitCore RCM4000
Page 6: ...RabbitCore RCM4100...
Page 12: ...6 RabbitCore RCM4000...
Page 20: ...14 RabbitCore RCM4000...
Page 46: ...40 RabbitCore RCM4000...
Page 68: ...62 RabbitCore RCM4000...
Page 82: ...76 RabbitCore RCM4000...
Page 96: ...90 RabbitCore RCM4000...
Page 114: ...108 RabbitCore RCM4000...
Page 118: ...112 RabbitCore RCM4000...
Page 122: ...116 RabbitCore RCM4000...
Page 124: ......