1260-112 User Manual
Module Operation 3-2
EADS North America Defense
Test and Services, Inc. © 2002
•
7-12 (open): When the switch is set to this position, the
module addresses of the plug-ins in the 1260-100 Carrier are
from 7 through 12, in the following pattern:
Front View – Module Addresses for 1260-100 Carrier
When setting module addresses for Adapt-a-Switch Carriers and
conventional 1260-Series modules, be sure that no address is
used by more than one plug-in or 1260-Series module.
For instructions on setting module addresses for a conventional
1260-Series module, see the label on the side panel of the
module.
Operating Modes
The 1260-112 may be operated either in
message-based
mode or
in
register-based
mode.
In the
message-based
mode, the 1260-01T switch controller
interprets commands sent by the slot 0 controller, and determines
the appropriate data to send to the control registers of the
1260-112 module.
A conceptual view of the message-based mode of operation is
shown in
Figure 3-1
below.