1260-X133 User Manual
Racal Instruments
©
2005
Module Operation 3-1
Chapter 3
MODULE OPERATION
Setting the
Module Address
The Option-01T switch controller identifies each Adapt-a-Switch
plug-in or conventional 1260-Series module by a
module address
that is unique to that module. The module address is a number
from 1 through 12, inclusive.
The module address assigned to the 1260-X133 is determined by
the carrier slot into which the 1260-X133 is inserted, and by the
position of the logical address DIP switch on the carrier side panel.
The logical address switch has two settings:
•
1-6: When the switch is set to this position, the module
addresses of the plug-ins in the 1260-100X Carrier are from 1
through 6. The module with address 1 is in the left slot of the
top row. The plug-ins are addressed in the following pattern:
Figure 3-1 Front View – Module Addresses for 1 through 6
1
2
3
4
5
6