07 - LabSat3 Battery
Battery operation and charging
LabSat 3 variants that include internal battery use replaceable Varta Li-Polymer battery packs. These packs are fully
certified (UL, CE, UN38.3 Transport). Each pack gives around 2 hours of record time. When the LabSat 3 is powered
externally, it will charge the internal battery pack if fitted and seamlessly switch over to battery operation when external
power is removed. Alternatively, an external battery charger is available to order.
To remove the battery from LabSat 3, unscrew the battery plate on the rear of the device and slide the battery out.
When operating from battery power, the battery charge status will be shown in the top-right section of the display -
If external power is connected and the battery is being charged, a power symbol will be shown over the battery symbol -
The discharge temperature range for the battery is -20°C to +60°C. Therefore, if the LabSat is operating from battery
power, it will power-down if the temperature falls outside this range.
The charge temperature range of the battery pack is 0°C to +45°C. Outside this temperature range, the LabSat will
switch off charging of the internal battery but will continue to operate from the external power supply.
https://racelogic.support/03LabSat_GPS_Simulators/LabSat_3/LabSat_3_User_Manual/
21
Summary of Contents for LabSat 3
Page 9: ...LabSat 3 Rear https racelogic support 03LabSat_GPS_Simulators LabSat_3 LabSat_3_User_Manual 9...
Page 42: ...https racelogic support 03LabSat_GPS_Simulators LabSat_3 LabSat_3_User_Manual 42...
Page 55: ...https racelogic support 03LabSat_GPS_Simulators LabSat_3 LabSat_3_User_Manual 55...
Page 57: ...https racelogic support 03LabSat_GPS_Simulators LabSat_3 LabSat_3_User_Manual 57...
Page 61: ...https racelogic support 03LabSat_GPS_Simulators LabSat_3 LabSat_3_User_Manual 61...