background image

 

 

Do not overfill the tank with petrol to avoid spilling. If you notice a spill, it must be wiped up completely with 

a dry cloth before starting the motor. 

 

If you swallow fuel by mistake, if you inhale fuel vapours or if you get drops of fuel in your eyes, see a doctor 

immediately. If a certain quantity of fuel is spilt on your skin or clothing, wash or change your clothes. 

 

Always stop the motor of the generator when filling it with fuel.   

 

Never fill the fuel tank while smoking or near a naked flame. 

 

Make sure you don’t spill fuel on the motor and the exhaust grille of the generator during filling with fuel.

 

 

Keep the fuel in an appropriate recipient and sheltered from any sources of fire. 

 

Carry out filling in a safe place, and slowly open the fuel cap to release the pressure which has built up inside 

the tank. Wipe up any drops of petrol that have spilled before starting the motor. 

 

To prevent fire, move the generator at least 4 metres away from the area for filling with fuel. 

 

Make sure that the fuel cap is tightly closed before starting. 

 

Do not keep petrol in the tank for a long time. 

 

While using or transporting the generator, make sure you keep the generator upright, otherwise the 

fuel may escape from the carburettor or the fuel tank. 

Electrical safety 

Before each use ensure that the load to be connected does not exceed the power of the current 

produced by the generator.

 

To avoid electric shock, you must follow the following instructions: 

 

Do not touch the generator with wet hands. 

 

Do not run the generator under rain or snow. 

 

Do not run the generator near water. 

 

Connect the generator to earth. Use a sufficiently thick conductor for the earth wire. 

 

Do not operate the generator in parallel with another generator. 

 

If using electrical extensions, make sure that they are sufficiently thick to transport the current and that they 

are used correctly. 

The  connection  of  a  generator  used  for  auxiliary  power  to  the  electrical  installation  of  a 

building  must  be  performed  by  a  qualified  electrician,  and  in  conformity  to  the  provisions  of  the 

applicable laws and norms in the field of electricity. Incorrect connections will cause leakage of the 

Summary of Contents for RAC3000

Page 1: ...INAL INSTRUCTION EN Gasoline Generator Instruction Manual Model RAC3000 BUILDER 32 rue Aristide Berg s ZI 31270 Cugnaux France Made in PRC 2017 Warning Please read the manual carefully before using th...

Page 2: ...rical System 2 Ground System 3 AC Applications 4 AC Operation 5 DC Operation 6 High Altitude Operation 5 PRE OPERATION CHECK 1 Engine Oil 2 Fuel Recommendation 6 STARTING STOPPING THE ENGINE 7 MAINTEN...

Page 3: ...children use this device Never let people who do not know these instructions use this device Local regulations may impose restrictions on the age of the user Please do not use this device when people...

Page 4: ...filter periodically and replace the air filter when necessary Remove any electrical equipment that is plugged in before starting or stopping the generator Before transporting the generator you must e...

Page 5: ...th fuel Make sure that the fuel cap is tightly closed before starting Do not keep petrol in the tank for a long time While using or transporting the generator make sure you keep the generator upright...

Page 6: ...ice connected is not designed to function with a voltage tolerance of 10 or a frequency tolerance of 3 compared with those of the generator Protection of the environment You must periodically check th...

Page 7: ...surface is very hot and not touching Keep away from the machine Exhaust emissions are harmful to health of body No naked fire near the machine Do not connect with the electricity system 2 COMPONENT ID...

Page 8: ...a time If the engine fails to start release the switch and wait 10 seconds before operating the starter again 2 Recoil Starter To start the engine pull the starter grip lightly until resistance is fel...

Page 9: ...d OFF automatically check that the appliance is working properly and does not exceed the rated load capacity of the circuit before switching the circuit breaker ON again The circuit breaker may be use...

Page 10: ...electrical current from the generator to feedback into the utility lines Such feedback may electrocute utility company workers or others who contact the lines during a power outage Consult the utilit...

Page 11: ...of the tool or appliance does not exceed that of the generator Never exceed the maximum power rating of the generator Power levels between rated and maximum may be used for no more than 30 minutes NO...

Page 12: ...n the battery and the generator are improper The indicator inside the DC circuit protector button will pop out to show that the DC circuit protector has switched off Wait a few minutes and push the bu...

Page 13: ...ct the other end of the positive battery cable to the battery positive terminal 6 Connect the vehicle ground cable to the battery negative terminal 7 Reconnect the vehicle grounded battery cable 6 Hig...

Page 14: ...ed to meet or exceed U S automobile manufacturer s requirements for Service Classification SG SF CC CD Motor oils classified SG SF CC CD will show this designation on the container SAE 10W 30 is recom...

Page 15: ...r prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN Use gasoline with a pump octane rating of 86 or higher We recommend unleaded gasoline because it produces fewer engine...

Page 16: ...s of your fuel system MTBE methyl tertiary butyl ether You may use gasoline containing up to 15 MTBE by volume Before using an oxygenated fuel try to confirm the fuel s contents Some states provinces...

Page 17: ...od of time it indicates that the battery should be recharged When the engine starts allow the engine switch to return to the ON position 1 Turn the choke lever or push the choke rod to the OPEN positi...

Page 18: ...ould be serviced by an authorized generator dealer unless the owner has the proper tools and is mechanically proficient 3 For professional commercial use long hours of operation to determine proper ma...

Page 19: ...hough this is unlikely unless you handle used oil on a daily basis it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handling used oil Please dispose of...

Page 20: ...aner cover clips remove the air cleaner cover and remove the element 2 Wash the element in a solution of household detergent and warm water then rinse thoroughly or wash in nonflammable or high flash...

Page 21: ...lug Service Recommended spark plugs F5T or F6TC or F7TJC or other equivalents To ensure proper engine operation the spark plug must be properly gapped and free of deposits If the engine has been runni...

Page 22: ...heat range Use only the recommended spark plugs or equivalent 8 TRANSPORTING STORAGE When transporting the generator turn the engine switch and the fuel valve OFF Keep the generator level to prevent...

Page 23: ...onditioner recommendations 1 Drain the carburetor by loosening the drain screw Drain the gasoline into a suitable container WARNING Gasoline is extremely flammable and is explosive under certain condi...

Page 24: ...fuel in the tank Refill the fuel tank NO Is there oil in the tank YES NO YES Is there spark from the spark plug Add the recommended oil Replace the spark plug NO Take the generator to an authorized g...

Page 25: ...circuit breaker ON Check the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO DEFECTS Replace the electrical appliance or equipment Tak...

Page 26: ...26 10 CIRCUIT DIAGRAM...

Page 27: ...27 11 SPECIFICATIONS...

Page 28: ...L 0 6 L Sound pressure level LpA 73 46 dB A K 2 0dB A Sound power level LwA 93 46 dB A K 2 0dB A Guaranteed sound power level 96 dB A Generator SET Generator set AC out put Voltage 230 V AC Frequency...

Page 29: ...Directive 2014 30 EU ROHS Directive 2011 65 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national standards and the following technical provisions EN IS...

Reviews: