Chapter 1 - Getting Started
Spin-Up Settings
11
NOTE:
If a hard address ID conflict occurs during Fibre Channel loop initialization, the
Fibre Channel protocol will dynamically set the drive IDs. This could cause
problems with some software products.
Switches 4, 5, and 6 are not used.
Spin-Up Settings
Switches 7 and 8 control the drive spin-up functions. The switches are directly attached to
all of the drive slot start signals. Switch 7 controls the “Start_1” signal (Delay Spin-up) and
switch 8 controls the “Start_2” signal (Remote Spin-up).
The table below describes the function of each switch.
“DL” Switch 7
“RM” Switch 8
Drive Spin-up Mode
Down (0)*
Down (0)*
Drive motor spins up at DC power on.
Down (0)
Up (1)
Drive motor spins up only on SCSI “start”
commands.
Up (1)
Down (0)
Drive motor spins up after a delay of 12 (may vary
depending on drive type) seconds times the
numeric ID setting of the associated drive.
Up (1)
Up (1)
Drive motor will not spin-up.
* Default setting for proper operation.