ver. 3.0
General parameters (11 GHz preliminary)
RAy3-11/18
RAy3-18
RAy3-11
Type
150 μs (66 B / 352 Mbps); <200 μs (1518 B / 352 Mbps);
<100 μs (66 B / 1010 Mbps); <150 μs (1518 B / 1010 Mbps)
Latency L2 (RFC 2544,
one way)
10240 Bytes
MTU (max packet
length)
Synchronous Ethernet; PTP (IEEE-1588v2 transparent clock)
Synchronization
Electrical
PoE active IEEE 802.3bt (POE++)
PoE passive 37– 60 VDC
DC 37 – 60 VDC
floating
Primary power
30 W for TX ≤ +17 dBm
up to 33 W for TX = +23 dBm
max 35 W (with SFP)
expected same as RAy3-18
Power consumption
(typ.)
System interfaces
USB 2.0, Host A; USB / WiFi; USB / ETH
USB
Mini WiFi 2.4 GHz b/g/n in USB slot (only for Alignment, Management &
Diagnostics) - included in basic configuration
WiFi
USB/Eth adapter in USB slot (only for Alignment, Management & Diagnostics)
- optional
Ethernet
Two contact sockets
RSS voltage
System status (multicolor)
Indication LED
Default settings, Configuration restore from internal backup
System button
Environmental
IP66
Ingress Protection
> 1.000.000 hours (> 114 years)
MTBF (Mean Time
Between Failure)
- 30 to + 55°C (ETSI EN 300019-1-4, class 4.1.)
Operating temperature
5 to 95% non-condensing
Operating humidity
4 kV (EN 61000-4-5)
Surge immunity
8 kV (EN 61000-4-2)
ESD resistance
Mechanical
FOD (Full Outdoor), direct mounting to antenna
Design & Mounting
Specific units for each Sub-band and for Lower (L) and Upper (U) part of the
band
Unit types
Rugged die-cast aluminium, compatible with RAy1 and RAy2
Casing
H×W×D: 160×245×245 mm (6.3×9.6×9.6 in)
Size
2.9 kg (6.4 lbs)
Weight
Class 3, 0.3 – 1.8 m, direct mounting (Jirous or LEAX/Arkivator or Shenglu
or others)
Antenna
Diagnostics & Monitoring
193
© RACOM s.r.o. – RAy3 Microwave Link
Technical parameters
Summary of Contents for RAy3-11