Important Points

Installations must comply with local water authority

bye-laws.
The Rada 566 is suitable for use with either steam

and water or hot and cold water.
Position mixing valve easily accessible for adjustment

and servicing.  Install with inlets horizontal and flat

face of cover vertical.  Check valves, where fitted,

must be installed in horizontal supply lines with caps

uppermost.
Flush supply lines until water is clear before

connecting mixing valve. Unless water supplies are

known to be clean strainers should be fitted,

positioned so that solids are trapped by screen and

fall to cap end e.g. unsuitable for use in rising
supplies.

Pressures

Minimum:

water 0.15 bar
steam 0.5 bar

Maximum:

water 8.25 bar
steam 7.0 bar

When in use, maintained pressures at inlets must not

exceed ratio of 5:1 (hot and cold water) or 3:1 (steam

and water).
If inlet pressures are unequal and either the outlet is

restricted or less than maximum flow used, due

allowance must be made for resulting increase in

pressure ratio.
Layout and sizing of pipework must be such that

when other services are used, pressures at inlets of

mixing valve are maintained as far as reasonably
possible and do not fall below recommended minimum.

Connections

Inlets/outlet: 1½" BSP.
Connect STEAM or HOT water to inlet marked RED

and COLD water to inlet marked BLUE.  Do not

confuse these markings with words hot' and 'cold',

which are cast in the cover as a temperature

regulating instruction.

Flow Control

The mixing valve does not control flow. It must be

fitted with either:-
(a)

Inlet stop valves and unrestricted outlet or

(b)

Inlet check valves and outlet stop cock.

Either method can be used for mixing hot and cold

water, or for mixing steam and water. where water

pressure exceeds steam pressure.
Note: Method (a) must be used when mixing steam

and water where steam pressure exceeds water

pressure.  When outlet flow control is used install

conveniently situated isolating valves for servicing

purposes.
If you are in doubt please contact us before

Maximum Temperature Setting

With steam pressure or hot water temperature at

normal, adjust to desired flow rate. Turn temperature

regulating handle to full clockwise position, then

check temperature at discharge point with the

thermometer.  If necessary, adjust as follows.

Remove acorn nut (620 11). temperature regulating

handle assembly (916 66) and spring (050 66).

Replace handle (without spring) in mid-position on

spindle, tighten acorn nut.  Turn handle clockwise to

increase, or anti-clockwise to decrease temperature,

until required maximum outlet temperature is obtained.
Taking care not to move spindle, remove acorn nut

and handle.  Replace spring, replace handle loosely

on spindle and press handle towards cover so spring

is compressed. Again taking care not to turn spindle,

turn handle clockwise until contact with stop plate

(110 66) is made and limit of travel reached.
Tighten acorn and recheck maximum temperature.

Reversed Inlets

If steam or hot water has been connected to cold

inlet and vice versa, this will be indicated by hot

water being obtained when cold is selected and vice

versa. Correct as follows:
Isolate mixing valve. Remove acorn nut, temperature

regulating handle and spring. Undo cover screws and

remove cover. Remove blanking screw (610 11).

Remove fouling plate screw (610 01) and fouling plate

(111 66), re-assembling fouling plate on opposite side

of base and replacing blanking screw in the hole

vacated by fouling plate screw.
Rotate port sleeve (014 68) through 180

o

, so cut-out

is opposite fouling plate. Slacken stop plate screws

(610 09) and turn thermostat assembly through 180

o

.

Tighten stop plate screws but do not over tighten.

Replace cover, locating thermostat assembly actuator

in slot at top of port sleeve. Replace and tighten

cover screws. Re-set maximum temperature. as

earlier described.

Maintenance

Periodical cleaning of internal parts will maintain the

mixing valve in good mechanical order.
Frequent movement of temperature regulating handle

will help keep port sleeve (014 68) from sticking due

to calcereous deposit.  A click will be heard as the

port sleeve reaches each limit of travel, indicating

that it is free.
To service mixing valve, first isolate supplies.

Dismantling

1.

Remove acorn nut, temperature regulating

handle and spring. Undo cover screws and lift

off cover.

2.

Slacken stop plate screws (610 09), then

remove thermostat assembly from cover by

pressing on end of spindle. Do not damage

spindle.

Rada 566 thermostatic mixing valve

INSTALLATION AND MAINTENANCE ADVICE

INSTALLER - This leaflet is the property of the customer and must be left with the user.

Summary of Contents for 566

Page 1: ...SHOWER FITTINGS Deutsch English Fran ais Italiano Japanese Nederlands rada C O L D H O T 566...

Page 2: ...so ist zu pr fen ob f r eine Wartung des Rada die ganze Anlage stillgelegt werden darf oder ob der Einbau von Vorabsperrungen in die Zuleitungen zum Rada n tig ist Wenn Sie ber irgend einen Punkt im...

Page 3: ...ulierring m ssen aber in jedem Falle fettfrei bleiben Der Einlaufzylinder muss eventuell mit einem weichen Hammer in seinen Sitz geklopft werden Den Thermostat ins Oberteil einsetzen und die Anschlagp...

Page 4: ...emperature at discharge point with the thermometer If necessary adjust as follows Remove acorn nut 620 11 temperature regulating handle assembly 916 66 and spring 050 66 Replace handle without spring...

Page 5: ...t assembly 909 06 Clack assembly water 909 10 Clack assembly steam 916 66 Temperature regulating handle assembly 925 70 Liner and sleeve assembly 1152 002 Cover joint Check Valves Check valves will no...

Page 6: ...tat et en s assurant que la manette soit en but e sur la plaque d arr t V rifier Ia temp rature maximale Arriv es invers es Si les arriv es ont t invers es corriger comme suit Bien isoler le mitigeur...

Page 7: ...joints toriques ceci facilit la position de cette pi ce dans la base 9 Replacer le thermostat dans le couvercle Resserrer les vis de la plaque d arr t sans forcer 10 V rifier le joint de couvercle 11...

Page 8: ...vapore o temperatura dell acqua calda a regime regolare Ia portata al valore desiderato Girare la maniglia di regolazione della temperatura in senso orario al massimo possible quindi verificare la tem...

Page 9: ...astra senza stringere troppo 10 Assicurarsi che la guarnizione del coperchio 1152 002 sia in posizione quindi ricollocare il coperchio stesso sul basamento accertandosi che il dente dell attuatore del...

Page 10: ...10 Rada 566...

Page 11: ...9 Screw stop plate 3 61011 Screw blanking 61051 Screw cover 8 61091 Screw 61287 Screw nameplate 2 62011 Acorn nut 63082 Seal liner centre or bottom 2 63085 Seal liner top 63431 Cap gasket 63968 Washer...

Page 12: ...aat moet worden gebruikt met a stopkranen in de inlaten en een open uitlaat of b keerkleppen in de inlaten en een stopkraan in de uitlaat Zowel de ene als de andere methode kan worden toegepast voor h...

Page 13: ...Om het weer inbrengen van een uitgenomen doorstroomkolom te vergemakkelijken verdient het aanbeveling de 0 ringen met wat vaseline in te vetten Het zal wellicht nodig zijn de doorstroomkolom op zijn p...

Page 14: ...1 66 110 66 641 20 050 66 045 88 639 68 620 11 612 87 916 66 610 09 610 51 1152 002 925 70 630 82 610 11 003 66 111 66 909 06 634 31 190 06 610 91 639 66 195 06 909 10 195 10 N F1 B K A mm in A 130 51...

Page 15: ...15 NOTES...

Page 16: ...16 P1227 7 Kohler Mira Limited August 2005 CUSTOMER CARE BJ RN HAMMER A S Stillingevej 47 Kr Stillinge 4200 Slagelse Tel 45 5854 7217 www bjornhammer dk www radacontrols dk...

Reviews: