- 13 -
When connected with the Integrated Outdoor Sensor, the
measured value (Outdoor temperature, humidity, wind
direction, wind gust and average, rainfall, UV and Sunlight
index, Dew point and feels like) will show up on the display
console.
Note:
Make sure that the distance between weather station
sensors and display console should be within 10ft (3m) to 100ft
(30m). If the weather station sensors is too close or too far
away, it may not receive a proper signal.
3.5 Sensor Operation Verification
The following steps verify proper operation of the sensors prior
to install the sensor array.
1.
Verify proper operation of the rain gauge.
Tip the
Integrated outdoor sensor back and forth several times. You
will heard a “ticking” sound within the rain gauge. Verify the
rain reading on the display console is not reading 0.00. Each
“ticking” represents 0.1 inch of rainfall.
2.
Verify proper operating of the wind speed.
Rotate the
wind cups manually or with a constant speed fan. Verify the
wind speed is not reading 0.0.
3.
Verify proper operation of in/outdoor temperature.
Verify the indoor and outdoor temperature match closely with
the console and sensor array in the same location (about 5 to
10’ (1.5 to 3 meters) apart). The sensors should be within 4°F
/2
°C
(the accuracy is ± 2°F/1
°C
). Allow about 30 minutes for
both sensors to stabilize.
4. Verify proper operation of in/outdoor humidity.
Verify
the indoor and outdoor humidity. Verify the indoor and outdoor
humidity match closely with the console and sensor array in