16.7.6  Menu 9.6 - Configure motor speed

The speed of the motor can be configured for recurring 
automatic functions if necessary (e.g. to reduce noise).

Recurring automatic commands are executed at the con-
figured motor speed.

Manual movement commands and the first automatic run 
after the system has been operated manually are always 
executed at maximum motor speed.

a) 

Set and confirm the 
desired speed.

=  low ...

=  medium ...

=  maximum ... 

 

  ... speed

1. 

Select and open  
menu

 9.6 Motor speed

.

+ -

+ -

Summary of Contents for 1615 45 11

Page 1: ... 2 1 11 20 Item No 1623 45 11 1623 60 11 Comfort DuoFern Plus 1615 45 11 Small belt Electronic Roller Shutter Belt Winder RolloTron Comfort DuoFern Translation of the Original Operating and Assembly Manual EN ...

Page 2: ...ght to you by all the highly qualified personnel here at RADEMACHER Dear Customer These instructions describe how to install the equipment connect the electrical system and operate your roller shutter belt winder Before you begin please read these instructions through completely and follow all the safety instructions This manual is a component of the product Please store it in an easily accessible...

Page 3: ...onnection 21 10 Drawing in and fastening the belt 22 11 Mounting the RolloTron Comfort DuoFern 24 12 Brief description of the button functions 25 12 1 Brief description of the standard display and main menu 26 12 2 Introduction to opening and closing the menus 27 13 Initial commissioning with the help of the installation wizard 28 14 Manual operation 32 14 1 Moving to a target position 33 14 2 Dis...

Page 4: ...nt configuration 67 16 7 3 Menu 9 3 Configure ventilation position 68 16 7 4 Menu 9 4 Configure continuous display lighting 69 16 7 5 Menu 9 5 Weekly programme configuration 70 16 7 6 Menu 9 6 Configure motor speed 71 16 7 7 Menu 9 7 Switch button lock on off 72 16 7 8 Menu 9 9 DuoFern settings overview 73 17 Erase all settings software reset 74 18 Carry out hardware reset 74 19 Removing the Rollo...

Page 5: ...us injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not avoided CAUTION This hazard may result in minor or moderate injury if not avoided ATTENTION This hazard may lead to property damage 1 2 Symbols and depictions used 1 Steps to be taken 2 Itemisation 1 List Please read the respective manual further useful information ...

Page 6: ...om this Children must not play with the device Cleaningandusermaintenancemaynotbecarriedout by children without supervision Watch the moving roller shutters whilst carrying out the settings and during normal operation and keep other people away from the area to avoid injury in the event the shutters suddenly slip Carry out all cleaning work on the roller shutters whilst the device is disconnected ...

Page 7: ... from RADEMACHER By doing so you avoid the risk of malfunctions and damage to your RolloTron Comfort DuoFern As the manufacturer we provide no guarantee for the use of third party components and accept no liability for consequential damage resulting from such All repairs to the RolloTron Comfort DuoFern must be undertakenbyauthorisedcustomerservicepersonnel Operating conditions Only operate the Ro...

Page 8: ... is a risk to life caused through short circuiting and electric shocks if the RolloTron Comfort DuoFern is used outside Never install or operate the RolloTron Comfort DuoFern outside Improper use can lead to serious injuries or property damage Never use the DuoFern radio system and its compo nents e g RolloTron Comfort DuoFern for remote controlofdevicesandsystemswithheightenedsafety relevant requ...

Page 9: ...g 4 Connection cable with Euro plug 5 Reel compartment cover 6 Cover plate 7 Traction relief mechanism incl assembly screws i also applies to item numbers 1623 60 11 1615 45 11 Afterunpackingpleasecheckandcompare the contents of the package with the above specified Check the details on the type plate Check that the voltage frequency on the type plate cor responds to the local mains conditions ...

Page 10: ...eel Fastening hook Traction relief Cable duct Connection socket for the light sensor Connecting terminals Reset button Minus button Fastening holes 4 General view item no 1623 45 11 Reel compartment cover Belt inlet Display Type plate also applies to item numbers 1623 60 11 1615 45 11 Disengaging bracket SET Stop button i ...

Page 11: ...OFFSET for Astro time Weekly programme Switching modes OFFSET NORMAL ASTRO SENSOR AUTO automatic mode Automatic mode off Timer periods Automatic dusk function Automated solar function Automatic dawn function Random function Wind display System settings DuoFern settings Wind speed metres second Brightness kilolux Temperature C Dimension percent SET value AUTO SOLL IST MO SO PLZ klx C m s ...

Page 12: ...hickness Maximum belt length 15 mm Small belt 1 0 mm 7 6 m 23 mm Standard belt 1 0 mm 7 6 m 15 m 1 3 mm 6 2 m 12 m 1 5 mm 5 2 m 11 m Table 2 Permissible shutter surface area m2 Roller shutter type Weight m2 Permissible shutter surface area m2 Plastic roller shutters 4 5 kg m2 Approx 6 m2 Approx 6 m2 Approx 10 m2 Aluminium and wooden roller shutters 10 0 kg m2 Approx 3 m2 Approx 3 m2 Approx 6 m2 Th...

Page 13: ... of the various func tions configuration options and possible combinations for the DuoFern system at http www rademacher de duofern i Central control of several DuoFern devices with a single RolloTron Comfort DuoFern A DuoFern network generally includes the DuoFern central operating unit or the HomePilot together with the associated user interface as the central control lers Alternatively you can ...

Page 14: ...posite direction and remove any possible obstacle Subsequently it is possible to operate the drive in the original direction again There is a risk of injury if the obstacle detection is not working The belt must be wound on as evenly as possible to ensure safe and correct functioning of the obstacle detection function Pleaseensurethatthebeltwindsasstraightandevenly as possible into the device duri...

Page 15: ...n 2 Direct drive to a position 0 100 3 Manual mode on off on off Off 4 Timer on off on off On 5 Random function 6 Automatic dawn function 7 Automatic dawn function on off on off Off 8 Automatic dusk function 9 Automatic dusk function on off on off Off 10 Sun function 11 Automatic solar function on off on off Off 12 Sunshine position 0 100 50 13 Ventilation position on off on off Off 14 Ventilating...

Page 16: ...utomatic darkness function with the Astro programme Automatic darkness function with connected light sensor Automatic solar function with light sensor Automatic dawn function with the Astro programme Random function Ventilating position End point setting Button lock System settings Permanent storage of the settings Automatic summer winter changeover Obstacle detection Overload cut off Soft start a...

Page 17: ...nto the device in order to avoid unnecessary friction and wear Incorrect installation can lead to property damage Strong forces are exerted during operation of the system which require secure installation on a firm base In order to ensure optimal operation the RolloTron Comfort DuoFern should not be installed near metal objects 8 1 You will require the following tools Screwdriver Scissors Carpente...

Page 18: ...that the belt box has suf ficient space to house the RolloTron Comfort DuoFern All dimensions in mm RolloTron Comfort DuoFern Item no 1615 45 11 small belt 1623 45 11 standard belt RolloTron Comfort DuoFern Plus Item no 1623 60 11 standard belt All dimensions in mm i ...

Page 19: ... an existing roller shutter system 2 1 Let the roller shutter move fully down until the slats are completely closed 2 2 Remove the old belt winder and unreel the belt 3 Prepare the belt 3 1 Cut the belt off approx 20 cm under the belt box 3 2 Fold the end of the belt over by approx 2 cm and cut a short slit in the centre This enables you to subsequently hook the belt onto the reel Recommendation T...

Page 20: ...allation and connection work only in an isolated zero volts state Disconnect all phases of the mains power supply cable and secure it to prevent any reconnection Check the system for a zero voltage status The electrical connection for the RolloTron Comfort DuoFern can be made either with the supplied con necting cable or via a fixed laid cable i i ...

Page 21: ...ble duct of the RolloTron Comfort DuoFern 3 Finally screw on the traction relief mechanism with the screws provided RolloTron Comfort DuoFern RolloTron Comfort DuoFern Plus Cable duct Traction relief Traction relief i WARNING WARNING A damaged connecting cable may cause a short circuit Pay attention that cables are laid safely Theconnectingcablemaynotbepinchedwhenscrew ing on the belt winder as th...

Page 22: ...he reel compartment when the motor is running 2 Press the Up button until the fastening hooks are easily accessible in the reel compartment i As no end points have been set yet the drive will stop as soon as you release the button 3 Always remove the mains plug from the socket 4 Next draw in the belt into the RolloTron Comfort DuoFern from the top i ...

Page 23: ...e fastening hooks from above 6 Re insert the mains plug into the socket 7 Press the Up button until the belt has wound completely once around the reel 8 Pull the belt tight when winding so that the deflection roller turns at the same time 9 Remove the mains plug again from the socket again 10 Finally place the provided reel compartment cover onto the reel compartment 10 Drawing in and fastening th...

Page 24: ...ise will be generated during operation 1 Slide the RolloTron Comfort DuoFern into the belt box and screw it tight using the screws provided WARNING WARNING A damaged connecting cable may cause a short circuit Ensure that the connecting cable is laid correctly inside the cable duct otherwise it can be crushed and damaged when the cover is screwed in place i 2 Slide the enclosed cover plate over the...

Page 25: ...n Configuration and movement to a target position OK button Confirms and opens the selected menu Confirm and save entry Continue to next entry Reset button see page 10 Carry out a hardware reset see page 74 Operating buttons Up Down Manual operation Up Down t t SET Stop button Configuration setting of various functions Manual roller shutter stop Menu button M Call up the main menu Back to previous...

Page 26: ...mfort DuoFern is only possible from the standard display Enables display and selection of the individual func tions and menus Displays the respective menu number Manual operation is not possible from the main menu No automatic switching commands will be executed during the configuration process If no button is pressed within 120 seconds the display automatically changes back to the standard displa...

Page 27: ... 120 s 3 Open the menu by press ing the OK button 4 Select the desired setting and confirm with OK 1 sec Briefly pressing the M button causes the display to go back one menu step If no button is pressed within approx 120 sec onds the display changes back to the standard display 5 Toggle back to the stand ard display In order to do so press and hold the M button for one second Pressing the M button...

Page 28: ...without an endpointsetting thedrivewillcontinuetorunforaslong as one of the two control buttons is actuated The automatic functions remain blocked until the end point setting is configured Please ensure that the belt is not excessively slack when reaching the lower end point ATTENTION Setting the wrong upper end point may lead to over load or damage the RolloTron Comfort DuoFern or the drive Do no...

Page 29: ...nd point Repeat points 1 a 1 e with the Down button 13 Initial commissioning with the help of the installation wizard i 3 Set and confirm the time Pressing the plus or minus button for an extended period causes the numbers to progress more quickly 4 Set and confirm the date day of the week month 5 Set and confirm the year 6 Set and confirm the first two digits of your Ger man postcode PLZ or the d...

Page 30: ...select between three switch ing time programmes from the weekly pro gramme see page 70 At this point the opening time is preconfigured as the weekly switching time MON SUN MO SO The previously con figured opening time is interpreted as earliest at xx xx hours Switching time mode See page 50 b If ASTRO is selected then the calculated opening time for the current day is displayed c Continue to set t...

Page 31: ...ard i Switching time mode See page 50 9 The standard display is shown as soon as the final setting is confirmed The RolloTron Comfort DuoFern is now ready for operation b If ASTRO is selected then the calculated clo sing time for the current day is displayed c Confirm the settings and return to the standard display SENSOR The roller shutters close every day at dusk as measured by the light sensor ...

Page 32: ...uses the roller shutters to stop in the interim 3 Closing the roller shutters Briefly pressing the button causes the roller shutters to move to the configured ventilation position or to the lower end point Ventilation position see page 68 If the ventilation position is con figured the roller shutters will first roll down to this position Pressing the Down button once more causes the roller shutter...

Page 33: ...utters are fully opened 100 the roller shutters are fully closed Automatic movement to a target position after approx two seconds The system will initiate movement to the configured target position automatically if no button is pressed for approx two seconds The ventilation position is ignored when moving to the target position 1 Display the current position of the roller shutters a In order to do...

Page 34: ...e page 43 Accessories see page 86 1 Accessing the weather data To do so briefly press the SET Stop button Initially the temperature is displayed An umbrella appears additionally on the display if the environmental sensor detects rain 2 Pressing the plus or minus button enables all of the weather data to be ac cessed successively a Brightness in kilolux klx b Wind speed in metres per second m s 3 B...

Page 35: ...ained from the login matrix on our website under www rademacher de The following section serves to describe all required Du oFern Settings for the RolloTron Comfort DuoFern The DuoFernSettings immediately affect the subsequent automatic function settings and the integration of the Rol loTron Comfort DuoFern into the DuoFern network Menu 9 9 DuoFern Settings The DuoFern settings are undertaken in m...

Page 36: ...evices is indi cated on the display Example 05 there are five DuoFern devices logged on 3 Select the desired mode On Activate login mode OFF Deactivate login mode Approx 120 seconds c Switch the desired DuoFern device to login mode d The new number of logged on devices is displayed after success ful login e g 06 The RolloTron starts up briefly by way of confir mation e Log in the next DuoFern devi...

Page 37: ...ogout e g 04 The RolloTron starts up briefly by way of confir mation e Log out the next Du oFern device or f Back to menu selection Deleting all logged on DuoFern devices 1 Select and open menu 9 9 1 Log on off 2 The number of logged on DuoFern devices is indi cated on the display 3 Delete all of the registered DuoFern devices To do so press the minus button for approx four seconds OFF flashes on ...

Page 38: ...ed DuoFern transmitters e g the DuoFern central operating unit cannot be logged off via this function 1 Select and open menu 9 9 1 Log on off 2 The number of logged on DuoFern devices is indi cated on the display 3 Activate the clear function In order to do so press and hold the SET Stop button for approx four seconds 4 Subsequently all currently registered DuoFern devices will be displayed e g 02...

Page 39: ...cal operation 1 DuoFern receiver The RolloTron Comfort DuoFern is integrated into a central automatic DuoFern network as receiver e g via a DuoFern central operating unit or Home Pilot etc In addition it can be remotely controlled by other DuoFern devices e g a DuoFern manual transmitter Function Not all local timer periods and automatic functions are available to the RolloTron Comfort DuoFern in ...

Page 40: ...ctions on the RolloTron Comfort DuoFern will be transmitted toallregisteredDuoFernreceiversandwillbeexecuted by the respective devices The RolloTron Comfort DuoFern is operated as a local roller shutter belt winder using its automatic functions and timer durations In addition control commands can also be received and executed from the DuoFern network e g from a DuoFern manual transmitter Function ...

Page 41: ...pted if the solar mode 3 is activated see next chapter 15 3 Menu 9 9 3 Setting the solar mode This function enables you to determine how the RolloTron ComfortDuoFernreactstosignalsfromalocallyconnected light sensor or control commands from a central sun shad ing controller e g a DuoFern radio sun sensor The subsequent configuration of the automated solar functions is correspondingly influenced by ...

Page 42: ...n and other registered DuoFern devices e g RolloTron Standard DuoFern are to be controlled by a light sensor connected to this device everydevice andeveryrollershutter istobestopped at an individually configured sunshine position Functions and settings for the automated solar func tion All roller shutters close to the configured sunshine position The solar limit value must be set 3 Central sun sha...

Page 43: ... data on off This menu enables you to switch the weather data dis play on and off If numerous environmental sensors are being received then you can additionally select the desired environmen tal sensor Environmental sensors update the weather data approx every 5 minutes For this reason it can take a few minutes until the weather data is displayed 1 Select and open menu 9 9 4 weather data 2 Switch ...

Page 44: ...ement 15 5 Menu 9 9 5 Display DuoFern address Each DuoFern device has its own unique address via which it communicates on the DuoFern network If necessary you can display the DuoFern address for the RolloTron Comfort DuoFern device 1 Select and open menu 9 9 5 DuoFern address a In each case two digits of the six digit address are shown in the form of a ticker 2 Back to menu selection 4 Select and ...

Page 45: ...l 55 4 Automatic solar function 58 5 Automatic dawn control 62 6 Random function 64 9 System settings 65 Standardised menu structure A standardised cross product menu structure has been developed for all RADEMACHER devices Similar functions always have the same menu number and therefore there may be gaps in the numbering i ...

Page 46: ...c dawn function Automatic dusk function Automated solar function Random function Manual operation is also possible in automatic mode Automatic mode off Icon in standard display All automatic functions are deactivated only manual operation is possible All automatic icons are switched off in the standard display i 16 1 AUTO Automatic mode brief description i ...

Page 47: ...tomatic mode on and off in the standard display 1 To do so press and hold OK for approx one sec ond in the standard display approx 1 s 2 Select and open menu 1 AUTO 3 Select and confirm the de sired setting On Automatic mode on OFF Automatic mode off 4 The main menu appears again once this is con firmed Automatic mode on Automatic mode off ...

Page 48: ... day and weekend switching times 3 Individual day switching times 1 Weekly switching times You can set two different switching times here 1 x opening time and 1 x closing time valid from Monday to Sunday MO SUN MO to SO 2 Working day and weekend switching times You can set four different switching times here 1 x opening time and 1 x closing time valid from Monday to Friday MO FRI MO to FR 1 x open...

Page 49: ...o setting the opening and closing times Application example for a second switching time You can use a second switching time for example to darken a child s bedroom at midday The first opening time has been set to 8 00 a m The roller shutters will open at 8 00 a m The roller shutters should close again at 12 00 noon and open again at 14 30 hours In order to do so a second switching time block must ...

Page 50: ...gured switching times Link to the opening time The roller shutters open at the daily calculated dawn time The configured opening time is inter preted as earliest at xx xx hours Example a Dawn begins at 5 00 a m The opening time has been set to 7 00 a m Your roller shutters will open at 7 00 a m Example b Dawn begins at 08 00 a m The opening time has been set to 7 00 a m Your roller shutters will o...

Page 51: ...witching times 3 Activate and confirm the switching times On Switching times on OFF Switching times off 4 Select and confirm a switching time block If the function is not acti vated proceed at point 5 1 The switching time setting is realised with a switching time mode 2 The switching time setting is realised without a switching time mode Example a In winter dusk begins for example at approx 17 00 ...

Page 52: ...page 50 Weekly switching times Working day weekend switching times Individual day switching times 5 Set and confirm an open ing time a Configure the switch ing time mode for the opening time 16 2 1 Menu 2 Configuration of opening and closing times The settings for the open ing and closing times are identical for all switching programmes The following serves to describe the procedure for setting an...

Page 53: ...gured closing time is interpreted as latest at xx xx hours SENSOR The roller shutters close every day at dusk as measured by the light sensor The previously con figured closing time is interpreted as latest at xx xx hours Switching time mode See page 50 b If ASTRO is selected then the calculated clos ing time for the current day is displayed c Return to main menu 7 Select the second switch ing blo...

Page 54: ...SOR is selected as the switching time mode thenthedesiredtwilightlimitvaluecanbeconfigured in menu 3 see page 57 16 2 1 Menu 2 Configuration of opening and closing times 8 Set and confirm the second opening time OFF The opening time is deactivated 9 Set and confirm the second closing time OFF The closing time is deactivated 10 Return to standard display after making the final setting The number of...

Page 55: ...position after approx 10 seconds The roller shutters will open again once the configured opening time is reached or in the event of a manual command The required twilight limit is configurable The automatic dusk function via light sensor is only executed once per day Mounting the light sensor see page 58 Automatic solar function The twilight time is recal culated every day based on the geographica...

Page 56: ...tching time mode Switch time mode see page 50 NORMAL ASTRO SENSOR 3 1 NORMAL No customisation is pos sible in NORMAL switch time mode 3 2 ASTRO Setting an offset The offset function can be used to modify the calcu lated Astro time by 60 minutes Example With a negative offset e g 10 the calculated Astro time is triggered 10 minutes earlier a Subsequently the resulting closing time is displayed b Re...

Page 57: ...ue is not met due to the onset of twilight the roller shutters will close ACTUAL IST value Currently measured brightness e g 12 22 too bright SET SOLL value Configurable set limit 01 very dark approx 4 Lux 15 less dark approx 40 Lux a Return to main menu 16 3 1 Menu 3 Customising the automatic dusk function ...

Page 58: ...s well as to the other devices on the DuoFern network Automatic solar function Automatic moving up and down of the roller shutter once a set limit is exceeded The roller shutter end position can be freely selected by changing the position of the light sensor on the window pane or by setting the sunshine position Example installation Light sensor see page 86 accessories Please note the state of the...

Page 59: ...times can be exceeded in the event of changing weather conditions 16 4 Automatic solar function brief description The automated solar function will be terminated and must be reactivated if required after the following events After manual actuation After execution of an automatic function After the upper end point is reached Automatic lowering If the sensor detects uninterrupted sunlight for 10 min...

Page 60: ...sation of the local solar set limit ACTUAL IST value Currently measured brightness e g 35 22 too dark SET SOLL value Configurable set limit 31 minimal sun approx 4000 Lux 45 bright sunlight approx 40000 Lux a Return to main menu or continue at point 5 Depending on solar mode see page 41 the following settings are required 1 Local light sensor Continue at point 4 2 Locallightsensorand sunshine posi...

Page 61: ...t sensor may not be covered by the roller shutters when they are moving down wards Set the sunshine position in a way that the roller shut ters remain above the light sensor Otherwise the light sensor cannot correctly measure the brightness level 5 Set the local sunshine position a Move the roller shutters to the desired position or b Enter the desired sunshine position by modifying the percent ag...

Page 62: ...ASTRO switch time mode Link to the opening time The previously configured opening time is interpreted as earliest at xx xx hours Configure a custom offset period The calculated dawn time can be customised to personal preferences by means of an offset between 60 and 60 minutes Thismeansthatitisnotnecessarytocontinuously readjust the closing time throughout the year Application example for the ASTRO...

Page 63: ...utomatic dawn con trol depending on the selected switching time mode Switch time mode see page 50 NORMAL ASTRO 3 1 NORMAL No customisation is pos sible in NORMAL switch time mode 3 2 ASTRO Setting an offset The offset function can be used to modify the calcu lated Astro time by 60 minutes a Return to main menu a Subsequently the resulting closing time is displayed b Return to main menu ...

Page 64: ... for manual movement commands Automatic movement commands triggered by sunlight and the automatic dusk control if triggered by light control The corresponding icon flashes in the standard display when the random function is activated during the period that the movement command is being delayed 1 Call up the main menu 2 Select and open menu 6 Random function 3 Select and confirm the desired setting...

Page 65: ...9 System settings brief description This menu enables you to configure additional device and system settings in order to customise your RolloTron Comfort DuoFern to your individual preferences and local conditions The procedure for opening and configuring a menu has previously been described on page 27 For this reason the following section serves to describe the individual system menus and their r...

Page 66: ...enu 9 1 Time date and postcode a Time b Date Day Month c Year Setting order d Postcode PLZ i Additional information about postcode Only the first two digits of the code are entered for German cities Please refer to the time zone table on page 85 for vari ous European cities ...

Page 67: ...t see page 28 2 Select and open menu 9 2 End points Additional information about configuring the end points The end points must be configured in order for the roller shutters to stop at the desired upper and lower positions It is imperative that both end points are configured oth erwise malfunctions may occur Observe the safety instructions for setting the end points on page 28 ...

Page 68: ...ly be closed completely via manual operation 1 Select and open menu 9 3 Ventilation posi tion Setting order a Activate or deactivate the ventilation position continue at b Return to menu System settings b Move the roller shutters to the desired position or c Enter the desired ventilation position by modifying the percent age value 0 the roller shutters are fully opened 100 the roller shutters are ...

Page 69: ...ull intensity Subsequently the brightness gradually fades down to the configured level 1 Select and open menu 9 4 Display lighting a Configure and confirm the desired brightness 0 Display lighting for the continu ous display is switched off 1 3 Brightness levels 3 Maximum brightness The display light remains permanently switched on at the configured level ...

Page 70: ...ribed starting on page 51 Double the amount of switching times by activating a second switching time block If you want to double the number of configurable open ing and closing times then you must activate a second switch time block n 2 here After this has been activated you can configure opening and closing times for both switch time blocks see page 49 1 Select and open menu 9 5 Weekly pro gramme...

Page 71: ...g to reduce noise Recurring automatic commands are executed at the con figured motor speed Manual movement commands and the first automatic run after the system has been operated manually are always executed at maximum motor speed a Set and confirm the desired speed 1 low 2 medium 3 maximum speed 1 Select and open menu 9 6 Motor speed ...

Page 72: ...irect activation in normal mode You can also activate and deactivate the button lock directly from the standard display The roller shutters can be moved manually even with the button lock activated Activate deactivate the button lock in the menu 1 Select and open menu 9 7 Button lock a Activate or deactivate the button lock On on OFF off Activate deactivate the button lock directly from the standa...

Page 73: ... in menu 9 9 and the respective sub menus here The menu overview for the DuoFern settings together with the corresponding reference pages are listed again here without their full description Menu 9 System settings Icon Menu Page 9 9 DuoFern settings 35 9 9 1 Logging on and off 36 9 9 2 Setting the DuoFern mode 39 9 9 3 Setting the solar mode 41 9 9 4 Switching weather data on off 43 9 9 5 Display ...

Page 74: ...fac tory settings Carry out the settings again as specified from page 28 onwards installation wizard 18 Carry out hardware reset A hardware reset can be carried out in the event that the RolloTron Comfort DuoFern fails to react to commands ATTENTION Never press the reset button when the motor is running as otherwise the end points will be modified A hardware reset causes the internal power supply ...

Page 75: ...on held down 4 Pull out the belt as far as possible from the top of the RolloTron Comfort DuoFern 5 Remove the cover plate from the lower mounting holes You can remove the front panel by gripping the small notch in the lower side of the device 6 Remove the mains plug from the socket 7 Subsequently release the fastening screws and pull the RolloTron Comfort DuoFern completely out of the belt box i ...

Page 76: ...n e g in the event of a move i CAUTION There is a risk of injury from the reel Never reach into the reel compartment when the motor is running Always remove the mains plug before touching the reel compartment 10 Subsequently remove the mains plug permanently from the socket 11 Release the belt from the fastening hook and pull it out completely from the front of the RolloTron Comfort DuoFern ...

Page 77: ...ust be overcome when pressing 4 Maintain pressure on the disengaging bracket and pull the belt out of the RolloTron as far as possible RolloTron Comfort DuoFern RolloTron Comfort DuoFern Plus i Drive release Storage bay Drive release WARNING WARNING There is a risk of injury as the roller shutters may slam shut or fall in an uncontrolled manner Secure the roller shutters from falling Hold on to th...

Page 78: ...d but the belt continued to wind and is no longer tight on the deflection roller b The lower end point is displaced due to elongation of the belt The belt may never be slack Reconfigure the lower end point see page 67 and ensure that the belt remains tight to the deflection roller In doing so the deflection roller must turn evenly the roller shutters no longer stop at the configured end points The...

Page 79: ...free and is jamming the roller shutters Open the roller shutter box and rectify the fault Lubricate any stiff areas with gliding wax if necessary d The roller shutters are too light Increase the weight of the roller shutters by for example adding a piece of flat steel to the bottom slat the roller shutters stop suddenly during upward travel a The drive may be jammed for example due to the roller s...

Page 80: ... RolloTron Comfort DuoFern will be opera tional again in approx 1 hour the RolloTron Comfort DuoFern no longer reacts to automatic commands and an error message Er02 is shown on the display a The RolloTron Comfort DuoFern is no longer ready for operation Carry out a hardware reset in accordance with page 74 b If the error persists after carrying out a hardware reset dismantle the RolloTron Comfort...

Page 81: ...ge Regularly check the RolloTron Comfort DuoFern for its correct functionality The shutters must not be damaged The belt must not be frayed The deflection roller on the roller shutter box must move freely The winding reel in the roller shutter box must be attached and stable After a longer period of use this may lose its stability Have damages components exchanged by a specia list firm Care You ca...

Page 82: ...ible ambient temperature 0 40 C Noise pressure level LpA 70 dB A Mains connecting cable 2 x 0 75 mm2 H03VVH2 F Transmission frequency 434 5 MHz Transmission power max 10 mW Range within a building 10 to 15 m Max number of DuoFern transmitters 20 Dimensions see page 18 Power reserve The RolloTron Comfort DuoFern has a power reserve of approx 8 hours Data retention subsequently to power failure All ...

Page 83: ... 2 3 4 5 6 7 24 Tractive force diagrams Lifting weight Kg 2 Belt thickness 1 0 mm 3 Belt thickness 1 3 mm 4 Belt thickness 1 5 mm 5 Belt length m 6 Belt lengths for RolloTron Comfort DuoFern 7 Belt lengths for RolloTron Comfort DuoFern Plus ...

Page 84: ... OFF random function OFF Time date 12 00 hours 01 12 2016 Postcode 34 Weekly programme 1 weekly switching times Maximum speed 3 Maximum in automatic mode Display backlighting 0 Automatic summer winter changeover On Button lock OFF Ventilating position OFF DuoFern mode 3 DuoFern receiver Solar mode 1 local light sensor Display weather data OFF ...

Page 85: ...168 Bergen 169 Trondheim Austria 170 Amstetten 171 Baden 172 Braunau 173 Brixen 174 Bruck Mur 175 Eisenstadt 176 Graz 177 Innsbruck 178 Klagenfurt 179 Landeck 180 Linz 181 Nenzing 182 Salzburg 183 Vienna Poland 184 Wroclaw 185 Bromberg 186 Danzig 187 Kattowitz 188 Krakow 189 Lodz 190 Lublin 191 Posen 192 Stettin 193 Warsaw Portugal 194 Faro 195 Lisbon 196 Porto Switzerland 197 Basel 198 Bern 199 A...

Page 86: ... is available for customising your RolloTron Comfort DuoFern to local conditions Further information about our accessories is available at the following website www rademacher de zubehoer Light sensor Item no Cable length 7000 00 88 0 75 m 7000 00 89 1 5 m 7000 00 90 3 m 7000 00 91 5 m 7000 00 92 10 m i The full text of the EU declaration of conformity is included with the product and is kept on f...

Page 87: ...or weathering Repairs and modifications by third party unauthor ised persons Use of unsuitable accessories Damage caused by unacceptable excess voltages e g lightning Operational malfunctions caused by radio frequency overlapping and other such radio interference For the warranty to be applicable the new device must havebeenpurchasedthroughoneofourapprovedspecial ist retailers Proof of this can be...

Page 88: ...r de Service Hotline 01807 933 171 Fax 49 2872 933 253 service rademacher de Subject to technical modifications misprints and errors Illustrations not binding 30 seconds free of charge subsequently 14 cents minute from German fixed line networks and max 42 cents minute from German cellular networks ...

Reviews: