56
EN
DANGER!
Risk of fatal electric shock when touching
electrical components.
◆
Carry out all installation and connection work only
in an isolated, de-energised state.
◆
Disconnect all phases of the mains power lead and
secure it to prevent any reconnection.
◆
Check that the system is de-energised.
WARNING!
WARNING!
Risk of short-circuit resulting from water in the
event of improper cabling.
◆
Never lay the motor cable
(13)
vertically upwards
otherwise water may collect on the cable and run
into the motor, leading to damage.
◆
Lay the cable in a loop. The loop will cause any
water on the cable to collect at the lowest point,
from where it can drain off.
8. Safety instructions for the electrical connection
WARNING!
WARNING!
Risk of short-circuit resulting from damaged
cable.
◆
Lay the motor cable
(13)
so that it cannot be dam-
aged by moving parts of the awning.
◆
The mains connection for the drive may only be
connected with the same conduction type. Con-
sult customer services if necessary.
◆
Seal the wall duct after laying the motor cable
(13)
in order to prevent water penetration.
Fixed-installation devices...
...must be equipped on the installation side with a
circuit-breaker for each phase in accordance with
DIN VDE 0700. Switches with a contact opening
width of min. 3 mm can be used as circuit-breakers
(e.g. power switch, power circuit breaker or residual-
current-operated circuit-breaker).