13. Technical specifications
n order to ensure trouble-free operation of
RADEMACHER tubular motors with KNX/EIB actua-
tors, the following parameters must be set prior to
commissioning:
Transient operation
If possible, transient operation (slat adjustment)
should be switched off.
e.g.
Mode for transient operation
Time: = 0 ms
14. Configuration of KNX/EIB actuators for RADEMACHER tubular motors
If transient operation cannot be deactivated
from within the software application...
...then you must ensure that the time between
transient operation and long-term operation on the
key sensor is less that the time between transient
operation and long-term operation on the actuator.
This will ensure that transient switch-off of the actua-
tor is prevented when holding the sensor key down.
Long-term operation
The motor
must
be switched off at the latest after
180 seconds.
e.g.
Basis for long-term operation
Basis: = 2.1 s
Factor: = 86
= (2.1 s x 86 = 180.6 s)
Motor series:
SLDSM xx/xx
PZ
Nominal torque:
Nm
30
40
50
No-load speed
rpm
16
16
12
Nominal voltage
V
230
230
230
Frequency
Hz
50
50
50
Nominal power
W
191
198
205
Current consumption
A
0.83
0.86
0.89
On-period (KB)
min.
4
4
4
Number of wires
5
5
5
Core cross section
mm
2
0.75
0.75
0.75
Plug-in connecting cable (rubber)
m
2,5
2,5
2,5
End switching range:
(number of revolutions.)
rev.
64
64
48
Insulation class
H
H
H
Protection class
I
I
I
Protection type in accordance with VDE 700
IP 44
IP 44
IP 44
Motor length without bearing
mm
546
546
546
Tube diameter
mm
45
45
45
Sound pressure level (LpA)
dB(A)
≤ 70
≤ 70
≤ 70
Transmission frequency
MHz
434.5
434.5
434.5
Max. transmission power
mW
10
10
10
Range approx.
- indoors (
depending on the building structure
)
m
30
30
30
- outdoors
m
100
100
100
Number of parallel tubular motors that can be connected
in parallel (when using RADEMACHER controllers,
e.g. Troll Comfort)
2
2
2
i