12
EN
After setting the brightness, now enter the delay time for the extension of the sun
shading.
B. Extension delay
This delay ensures that the sun shading does not constantly extend and retract in the
event of rapidly changing light conditions.
The default setting for the extension is 1 minute. The brightness must therefore lie above
the entered set value (point A of the automatic settings) continuously for 1 minute
before the sun shading is extended. The sun shading therefore reacts quickly to sun.
Adjust the value with (higher) and (lower). Then press
SET
to proceed to the
setting of the next parameter.
After setting the extension delay, now enter the delay time for the retraction of the
sun shading.
C. Retraction delay
The default setting for the retraction
is 12 minutes. The brightness must
therefore lie below the entered set
value (point A of the automatic settings)
continuously for 12 minutes before the
sun shading is retracted. Passing
clouds are “masked” in this way.
i
i