41
EN
Service
Calling up service data
The software version of the operating unit and weather station can be shown on the
display. The service area can be called up from the basic settings by holding the
SET
button depressed (3 seconds). The software version of the operating unit (
)
is displayed first; press the
SET
button briefly to display the software version of the
controller/weather station (
). Display 10 means version 1.0, 12 means 1.2, etc.
Exit the service data display by pressing the
SET
button again.
The following default settings are stored for automatic mode on delivery of the ReWiSo
controller:
u
Sun shading from sun intensity > 40 kLux
u
Delay time in the case of sun until the sun shading
- extends: 1 min,
- retracts: 12 min
u
Blocking until the indoor temperature > 18°C
u
Blocking until the outdoor temperature > 5°C
u
Wind alarm from 4 m/s
u
Rain alarm activated
Factory settings