2.3 Technical Term - Definition
DuoFern
◆
RADEMACHER radio technology for controlling
compatible products.
WR Config-Tool
◆
RADEMACHER software for programming the
DuoFern system incl. automatic software update
for the DuoFern manual central operating unit.
HomePilot®
◆
The HomePilot® is a central controller unit for
RADEMACHER radio products.
DIN EN 13659
"Shutters and external Venetian blinds - Performance
requirements including safety."
◆
This standard determines the performance require-
ments that externally attached shutters and blinds
must fulfil. It also contains significant hazards with
regard to the design, transportation, installation,
operation and maintenance of these shutters and
blinds.
Blinds
◆
Roller shutters
Obstacle detection
◆
If the roller shutters hit an obstacle in the DOWN
(
t
) direction, the RolloTron Basic DuoFern 1200 is
switched off, see page 59.
Overload cut-off
◆
If the drive jams in the UP (
▲
) direction (for exam-
ple, due to ice), the RolloTron Basic DuoFern 1200 is
switched off, see page 59.
End points
◆
An end point is defined and set for each running di-
rection of the roller shutter. Once this point has been
reached, the RolloTron Basic DuoFern 1200 switches
off and the roller shutter stops.
Running Time Limit - Transient Operation (KB)
◆
The roller shutter belt winder RolloTron Basic
DuoFern 1200 is not designed for continuous op-
eration. Transient operation defined the maximum