76
EN
22. Removing the belt in the event of unit failure
In the event that the RolloTron Comfort DuoFern unit fails
and the motor no longer runs, you can use the disengaging
bracket provided in order to fully remove the belt from the
belt winder unit, without the need for cutting it.
1.
Remove the mains plug from the socket.
2.
Dismantle the RolloTron Comfort DuoFern as
previously demonstrated on page 74.
3.
Release the drive with the help of the supplied
disengaging bracket.
ATTENTION
◆
Hold on to the belt tightly, as otherwise the roller
shutters may slam shut.
◆
A small amount of resistance must be overcome when
pressing.
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the RolloTron as far as possible.
5.
Release the belt from the fastening hook and pull it out
completely from the RolloTron.