16
EN
10. Manual setting of end points
WARNING!
Risk of fatal injury (electric shock) caused by tearing off the motor cable.
• Ensure that the motor cable is not taken up by the winding shaft and torn off during the setting
process.
Important conditions for setting the end points and for safe operation.
• End points must be set in order to switch off the motor when they are reached for both directions of
travel, up (
p
)/down (
q
).
• The tubular motor must be fully installed.
• There must be a suitably fixed limit (e.g. window sill) in the area of the lower end point if the end point
is to be configured automatically.
ATTENTION!
The roller shutter may be damaged in case of incorrect manual setting of the end points.
• Never dismantle the mechanical stoppers or the end rail from the final roller shutter slat.
• Do not knock against the mechanical stoppers and maintain a safety gap of 2 - 3 cm.
The tubular motors are designed for transient operation (approx. 4 min.).
If this period is exceeded, or if the equipment is switched over frequently, then the motor may heat up
and the thermal protection system will switch it off.
• In this case, allow the motor to cool down for 20 minutes.
Modifying the end points
Move the roller shutter back to the centre position and begin the process again.
CAUTION!
Risk of crushing injuries to the hand when working with the roller shutter box open.
• Never reach into the area of the winding shaft when the motor is running.
11. Test run / modifying the end points
ATTENTION!
RA_VBD_100-007-1_RolloTube_105x148_8x_1c_220204.indd 16
04.02.22 11:43