15
i
[ 3 ]
[ 4 ]
[ 5 ]
EN
7. Important information prior to electrical installation and mounting
Installation and electrical connection of the Troll Basic DuoFern may only be
undertaken with the supplied installation housing [ 3 ].
The connecting terminals
[ 4 ]
are located at the bottom of the installation housing
[ 3 ]
.
NOTE
Installation housings for other variants of the Troll controller are not compatible.
Parallel connection of electronic tubular motors
A maximum of 3 tubular motors can be connected in parallel to the Troll Basic DuoFern (e.g.
RADEMACHER electronic tubular motors).
To do so, please refer to the operating manual for the corresponding tubular motor.
Parallel connection of mechanical tubular motors
A cut-off relay is required in order to connect mechanical tubular motors in parallel.