A P P E N D I C E S
88
Series 8000™ O&M Manual
5.3.43
"JPB firmware update failed"
The automatic installation of new firmware on the jog panel did not
complete successfully.
Troubleshooting:
1.
Clear the fault and verify system is operating normally.
2.
If not, cycle power at the drive cabinet.
3.
If issues persist, contact support.
5.3.44
"Ephemeris data file needs update”
"TLE ephemeris data file needs update”
"IESS e
phemeris data file needs update”
The ephemeris data for the selected target is older than 170 hours.
This happens if the ACU loses its internet connection or if ephemeris
data for a target is no longer reliable. To clear the fault:
•
Restore the network connection, which will cause the ACU to
update the data.
Or…
•
Double-tap the Home > Fault button to clear the
alert
—
if the
issue isn’t addressed, the system may
report the fault again.
5.3.45
"Fault condition forced standby"
Standby mode was asserted by the system in response to a detected
fault. Clear the fault condition and resume operation. If the fault con-
dition still exists, the fault will be re-asserted.
5.3.46
"Can't access settings file"
Another instance of acu.exe has the settings file open. Quit the ACU
application (Home > Setup > About > Quit). Use Windows Task
Manager to kill any other instances of acu.exe, then restart the ACU.