T Y P I C A L O P E R A T I O N S
Series 8000™ O&M Manual
63
4.6.4.1
Requirements for TLE and IESS
–
412
The ACU auto-updates its TLE and IESS
–
412 data daily, if it has web
access.
•
Internet connection to the network connector (located on the
ACU
’s
back panel; see section 3.3).
If no internet connection is available:
o
The data may be updated over internal LAN.
Choose Setup > About > Desktop to access Windows and
ensure the directory at C:\Radeus Labs is shared with write
permission. Copy geo.txt (for TLE) or satlist.csv (for IESS-
412) into it, from wherever it’s located on the LAN.
o
The data may be transferred via USB drive.
Insert a USB drive containing the data file into the USB in-
terface on the ACU
’s front panel. Use the ACU’s Windows
interface (Setup > About > Desktop) to copy the data into
C:\Radeus Labs.
•
IESS-412 and TLE (SGP4) modes are not available for Default or
Immediate targets.
To use either of those modes, first choose
Target > New or edit an existing target.
•
Encoder offsets must be non-zero values.
•
The antenna
’s
coordinates must be set.
It is recommended to have the system synced to a timing source so
the ephemeris calculated movements performed by the antenna are
synced to the movements of the target satellite. This can be done
through the built-in Windows NTP service or IRIG if that option was
purchased.
When providing custom TLE or IESS data, the ACU should
be configured to disable automatic TLE download. Other-
wise, any custom TLE data will be overwritten. See Appen-
dix A-10.4.1
Disable automatic TLE download
” for details.
The ACU checks the C:\Radeus Labs directory every second for
sources of TLE or IESS data. To force the ACU to use new data, de-
lete geo-local.txt and supply new TLE data using the above methods.