A P P E N D I C E S
86
Series 8000™ O&M Manual
5.3.36
"IOC firmware update failed"
The automatic installation of new firmware on the I/O controller did
not complete successfully. Contact supplier for service or support.
Troubleshooting:
1.
Clear the fault and verify system is operating normally.
2.
If not, cycle power at the drive cabinet.
3.
If issues persist, contact support.
5.3.37
"IOC2 firmware update failed"
See preceding, but applied to the secondary I/O controller board.
5.3.38
"ENC communication failure"
"ENC2 communication failure"
The ACU cannot communicate with the encoder board.
Troubleshooting:
1.
Verify the drive cabinet is turned on.
2.
Verify power supplies in drive cabinet are turned on, check the
Ethernet connection(s).
3.
Verify IFL from the drive cabinet is connected to the ACU
4.
Verify the appropriate position feedback is selected in
Setup > Encoders > Type
5.3.39
"ENC firmware update failed"
The automatic installation of new firmware on the encoder did not
complete successfully.
Troubleshooting:
1.
Clear the fault and verify system is operating normally.
2.
If not, cycle power at the drive cabinet.
3.
If issues persist, contact support.