PROBLEM
CAUSE
REMEDY
Machine will not operate
Not connected to power source
Connect to power source
Building circuit breaker or fuse
blown
Reset breaker or replace fuse
Machine door does not make
contact with the door switch
Readjust switch to make contact with
door switch screw when door is closed
Motor thermal protector activated Allow to cool, then restart
Machine circuit breaker tripped
Reset by pressing circuit breaker back in
Faulty Control Panel
Contact Red Devil Equipment Co.
Customer Care
Faulty Motor
Contact Red Devil Equipment Co.
Customer Care
Worn, damaged, or loose drive
belt
Unplug power cord, open mixer door, and
visually inspect the drive belt
Emergency E-STOP push-button
is activated
Turn switch knob 1/4-turn clockwise to
disengage
Excessive Vibration
Pail damaged
Fix or replace pail
Can not properly seated
Reset can into holder
Feet are not level
Adjust and level feet
Machine does not shut off
when door is opened
Faulty door limit switch
Contact Red Devil Equipment Co.
Customer Care
Machine does not shut off at
the end of a mix cycle
Faulty timer
Contact Red Devil Equipment Co.
Customer Care
Increasing mechanical noise Bearings worn or damaged
Contact Red Devil Equipment Co.
Customer Care
Pail rotates inside the
clamping plates
Top clamp pad worn
Replace pad
Top clamp not secure
Turn the crank handle down until top
plate is snug on pail
Contact Radia's Customer Care
Contact Radia's Customer Care
Contact Radia's Customer Care
Contact Radia's Customer Care
Contact Radia's Customer Care
Top Plate
6. Troubleshooting