Owner’s Manual – Gas Storage
7
H3958 026271 Rev. A
N
ote: Commissioning adjustments
must be done only by a licensed
tradesperson.
Lighting the Water Heater
The water heater must be filled with
water before lighting. Instructions for
lighting procedure are on the inside of
the access cover and shown below:
1. Turn the knob fully clockwise to the
“•” (off) position.
2. Wait 5 minutes so any build-up of
unburnt gas can escape.
3. Turn the knob to the
(pilot)
position.
Thermostat and
gas control knob
Igniter
4. Depress the knob fully (until
disappears below housing) and
after 30 seconds, whilst keeping
the knob depressed, repeatedly
press the igniter button (for up to 40
seconds) until the pilot flame ignites.
Note:
It is not possible to depress
the knob fully if the gas control has
activated its safety shut-off feature.
In this case, wait 60 seconds for the
gas control to reset.
5. Keep the knob depressed for 20
seconds after the pilot flame lights.
The pilot flame can be observed if
a mirror is placed directly below the
pilot assembly.
6. Release the knob and check if the
pilot is still alight.
7. If pilot has failed to light or has not
remained alight, turn gas control
knob to “•” (off). Wait 5 minutes for
the escape of unburnt gas, then
begin again at step 3.
8. When the pilot flame remains alight
with the knob released, turn the
knob anticlockwise to one of the
number settings. A setting of “6” is
recommended and this will give a
water temperature of about 60ºC.
9. Turn the knob to a higher number
for higher water temperatures or
a lower number for lower water
temperatures.
10.
Set the test point pressure as
per the instructions on page 8.
11. Replace the access panel and
ensure that it is firmly in position
before operating the appliance.
12. If the burner does not light at
the selected setting, the water
Commissioning Adjustments