PERFORMANCE

 

RATINGS 

 

ES50LVP 

 

Performance Data - Hot Water Capacities (BTUH) @ 70°F Entering Air Temperature 

WATER PD 

(FT-WG) 

@140°F 

ecosmart 

Air Pressure Drop: 0.04 IWC 

ES50LVP 

Entering Water Temperature 

CFM 

GPM 

110°F 

120°F 

130°F 

140°F 

150°F 

160°F 

170°F 

180°F 

300 

10,640 

13,320 

16,010 

18,700 

21,400 

24,100 

26,800 

29,500 

4.38 

10,910 

13,650 

16,400 

19,160 

21,910 

24,670 

27,430 

30,190 

4.83 

11,070 

13,850 

16,640 

19,430 

22,220 

25,020 

27,820 

30,610 

7.23 

400 

13,170 

16,510 

19,850 

23,200 

26,550 

29,910 

33,270 

36,640 

4.38 

13,640 

17,080 

20,530 

23,980 

27,440 

30,900 

34,370 

37,840 

4.83 

13,920 

17,430 

20,940 

24,460 

27,990 

31,510 

35,040 

38,570 

7.23 

500 

15,370 

19,260 

23,170 

27,090 

31,020 

34,950 

38,890 

42,840 

4.38 

16,050 

20,100 

24,170 

28,250 

32,330 

36,420 

40,520 

44,620 

4.83 

16,470 

20,630 

24,790 

28,970 

33,150 

37,340 

41,530 

45,720 

7.23 

600 

17,280 

21,660 

26,070 

30,490 

34,920 

39,360 

43,810 

48,260 

4.38 

18,190 

22,800 

27,420 

32,050 

36,700 

41,350 

46,010 

50,670 

4.83 

18,770 

23,510 

28,270 

33,040 

37,810 

42,600 

47,390 

52,180 

7.23 

700 

18,950 

23,780 

28,620 

33,480 

38,360 

43,250 

48,140 

53,040 

4.38 

20,110 

25,210 

30,330 

35,470 

40,620 

45,770 

50,940 

56,110 

4.83 

20,850 

26,130 

31,420 

36,730 

42,050 

47,380 

52,710 

58,050 

7.23 

800 

20,440 

25,650 

30,880 

36,140 

41,410 

46,690 

51,980 

57,280 

4.38 

21,840 

27,390 

32,960 

38,550 

44,150 

49,770 

55,390 

61,020 

4.83 

22,740 

28,510 

34,300 

40,100 

45,920 

51,740 

57,580 

63,420 

7.23 

900 

21,760 

27,310 

32,900 

38,500 

44,120 

49,760 

55,410 

61,070 

4.38 

23,400 

29,360 

35,340 

41,340 

47,360 

53,390 

59,430 

65,490 

4.83 

24,480 

30,690 

36,930 

43,190 

49,460 

55,750 

62,040 

68,340 

7.23 

 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for EcoSmart ES50LVP

Page 1: ...P N 14000A PRERAD ES50LVP ES90LVP PREMIUM MODULATING AIR HANDLER Installation Operation and Maintenance Manual RADIANT 101 Sharer Road Woodbridge ON L4L 8Z3 Tel 905 265 1527 Fax 905 265 9739 ...

Page 2: ...11 Rear Piping Connections 11 Ecosmart Mounting 12 Plumbing 12 Pump 13 PIPING DIAGRAMS 15 Typical Tankless Water Heater Piping 15 Typical Boiler Piping 16 ELECTRICAL 17 Electrical Information 17 Thermostat Wiring 17 Ecosmart ES50LVP ES90LVP Wiring Diagram 18 Miscellaneous Wiring 19 DIP SWITCH OPTIONS 20 Switch Locations 20 Outdoor Temperature Select 20 Heat CFM ES90LVP 21 Heat CFM ES50LVP 21 Syste...

Page 3: ...E AND MAINTENANCE 26 Filter 26 Coils 26 Fan and Motor 26 Control and Blower Assembly Removal 26 TROUBLESHOOTING 27 Thermostat call error 27 External pump does not run 27 External pump is noisy at start up 27 Water heater temperature and pressure relief valve is weeping 27 Insufficient or no heat 27 Cold water at hot faucet 28 Fan runs for cooling but not for heating 28 Heating during standby mode ...

Page 4: ... damage WARNING Improper installation may create a condition where the operation of the product could cause personal injury or property damage Only a qualified contractor installer or service agency should install this product Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for assistance CAUTION This product must be insta...

Page 5: ...r to adjust for a wide variety of installations Various parameters are automatically monitored and fan and pump speeds vary simultaneously The ecosmart has a built in variable speed pump controller that can vary the speed of a standard single speed AC pump MODES OF OPERATION Three modes of operation are available 1 Full modulation full control of fan and pump requires outdoor temperature sensor 2 ...

Page 6: ... outdoor sensor not installed Water temperature is set at the heat generator by referring to the heat generator performance data Fan operates at 50 of the HEAT CFM setting for 5 minutes then increases to 75 for a further 5 minutes then increases to 100 until the thermostat is satisfied If the pump is controlled by the ecosmart its speed will be adjusted accordingly as the ecosmart goes through its...

Page 7: ...40 4 38 4 16 050 20 100 24 170 28 250 32 330 36 420 40 520 44 620 4 83 5 16 470 20 630 24 790 28 970 33 150 37 340 41 530 45 720 7 23 600 3 17 280 21 660 26 070 30 490 34 920 39 360 43 810 48 260 4 38 4 18 190 22 800 27 420 32 050 36 700 41 350 46 010 50 670 4 83 5 18 770 23 510 28 270 33 040 37 810 42 600 47 390 52 180 7 23 700 3 18 950 23 780 28 620 33 480 38 360 43 250 48 140 53 040 4 38 4 20 1...

Page 8: ...680 63 050 69 420 6 27 900 3 24 040 30 150 36 290 42 450 48 610 54 790 60 980 67 180 4 05 4 25 850 32 400 38 980 45 570 52 180 58 800 65 420 72 050 4 19 5 27 010 33 850 40 710 47 580 54 460 61 360 68 260 75 160 6 27 1 000 3 25 430 31 900 38 400 44 920 51 460 58 000 64 560 71 130 4 05 4 27 530 34 520 41 530 48 560 55 610 62 670 69 740 76 810 4 19 5 28 900 36 220 43 560 50 920 58 300 65 690 73 080 8...

Page 9: ...DATA INCHES Model Overall Dimensions W x D x H Supply Opening W x D Side Return Piping Location A B C D E F G H I J K ES50LVS 14 0 21 0 29 0 11 8 17 8 18 3 14 3 1 4 2 0 2 8 2 4 ES90LVS 21 0 21 0 29 0 18 8 17 8 18 3 14 3 1 4 2 0 2 8 2 4 ...

Page 10: ...x 30 5 ES50LVP ECM blower performance amps CFM 0 1 WC 0 2 WC 0 3 WC 0 4 WC 0 5 WC 300 0 30 0 46 0 69 0 82 1 04 400 0 54 0 65 0 82 0 85 1 13 500 0 66 0 77 0 95 1 20 1 41 600 0 90 0 92 1 29 1 49 1 67 700 1 01 1 35 1 44 1 77 2 02 800 1 55 1 59 1 76 2 11 2 45 900 1 86 1 88 2 12 2 40 2 80 ES90LVP ECM blower performance amps CFM 0 1 WC 0 2 WC 0 3 WC 0 4 WC 0 5 WC 600 0 94 0 99 1 26 1 58 1 95 700 1 22 1 ...

Page 11: ...rt the hot water generating equipment per the manufacturer s recommendations Set the design water temperature to deliver the necessary amount of BTUs to the air handler 5 Once all air has been purged turn on the power to the ecosmart and set the room thermostat to heat and set the temperature high enough to initiate a call for heat This will energize the air handler an in turn the fan and pump 6 O...

Page 12: ...n unheated space Should the ecosmart be installed in an area where the ambient temperature may fall below freezing ethylene or propylene glycol should be added into the hydronic heating system to protect against damage which would not be covered under warranty Make sure the glycol is compatible with all system components and is permitted by local and national codes Rear Piping Connections The heat...

Page 13: ...the cabinet or from the bottom of the cabinet Position a filter rack so that the filter is readily accessible A filter and filter rack are not included Sides are marked for a standard 16 x 20 in filter rack WARNING Special care should be taken in the vicinity of the coil to avoid puncture Screw into opening flange instead of top of cabinet when fastening the supply air duct Plumbing Install a sedi...

Page 14: ...ed for your system to meet local codes and to work effectively A check valve Protects against back flow of water to avoid short circuiting around the water heater during domestic use Protects against thermal siphoning Is required in all potable water systems Pump A pump is not included inside the ecosmart Whether you are using an external pump or an internal built in pump it should be sized for th...

Page 15: ... the equipment has been refilled and all air is purged from the system before turning on the heater WARNING When the system requires water temperatures higher than 120F a mixing valve shall be installed to reduce domestic hot water temperature to safeguard against scalding Combo Systems The ecosmart is ideal for use in combo systems which provide space heating and domestic hot water from a single ...

Page 16: ...15 P a g e PIPING DIAGRAMS Typical Tankless Water Heater Piping ...

Page 17: ...16 P a g e Typical Boiler Piping ...

Page 18: ...ront panel Ratings data is located on the lower front panel The ecosmart operates on 120VAC 60Hz single phase line voltage All control circuits are standard 24VAC ecosmart must be grounded via the green wire within the control box Thermostat Wiring Any standard heat cool thermostat is compatible with the ecosmart Wire thermostat to lower right tabs as marked The ecosmart supports optional 2 stage ...

Page 19: ...18 P a g e Ecosmart ES50LVP ES90LVP Wiring Diagram ...

Page 20: ...h If there is a call for DHW fan will shut down and resume once the call for DHW has ended BOILER dry contacts to initiate heat source AUX 24V 24VAC output for humidifier or other accessory Active when heating is on OUTDOOR included outdoor temperature sensor connects here If sensor is not connected ecosmart assumes coldest temperature is present ...

Page 21: ...w OUTDOOR TEMP set the lowest outdoor temperature expected HEAT CFM set 1 of 8 fan CFM rates for heating SYSTEM set various system parameters COOL CFM set 1 of 8 fan CFM rates for cooling Outdoor Temperature Select Select lowest possible expected outdoor temperature DESIGN TEMP C DESIGN TEMP F SWITCH 1 SWITCH 2 SWITCH 3 18 0 OFF OFF OFF 17 to 10 1 14 ON OFF OFF 9 to 0 15 32 OFF ON OFF 1 to 10 33 5...

Page 22: ...WITCH 1 SWITCH 2 SWITCH 3 300 OFF OFF OFF 400 ON OFF OFF 500 OFF ON OFF 600 ON ON OFF 700 OFF OFF ON 800 ON OFF ON 900 OFF ON ON System ES990LVP and ES50LVP Select required system parameters Mode SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 Full Modulation OFF OFF X X Step Modulation ON OFF X X Single Stage OFF ON X X Test Mode 1 ON ON X X Normal Fan Cooling 2 X X OFF X Dehumidification Fan Cooling 2 X X O...

Page 23: ... for 15 min and then reverts back to rate set by COOL CFM 3 Normal Continuous Fan runs at rate set by HEAT CFM switch Low speed Continuous Fan runs at 50 of rate set by HEAT CFM switch Cool CFM ES90LVP CFM 0 5 WC SWITCH 1 SWITCH 2 SWITCH 3 600 OFF OFF OFF 700 ON OFF OFF 800 OFF ON OFF 900 ON ON OFF 1000 OFF OFF ON 1100 ON OFF ON 1200 OFF ON ON 1300 ON ON ON Cool CFM ES50LVP CFM 0 5 WC SWITCH 1 SWI...

Page 24: ...ed R is disconnected from W Heat generator is turned off Auxiliary 24VAC power is turned off Pump turns off and fan speed ramps down to zero extracting any remaining heat in the coil Step Modulation Heating Mode ecosmart outdoor sensor not installed Thermostat calls for heat R is connected to W Heat generator is turned on Auxiliary 24VAC power is turned on Pump turns on 100 After a 15 second delay...

Page 25: ... on Pump turns on at 100 After a 15 second delay to allow for system water to heat up coil fan ramps up to HEAT CFM speed Thermostat is satisfied R is disconnected from W Heat generator is turned off Auxiliary 24VAC power is turned off Pump turns off and fan speed ramps down to zero extracting any remaining heat in the coil Cooling Mode Modulation Step and Basic ecosmart outdoor sensor not install...

Page 26: ...ate If SYSTEM switch 4 is ON fan runs at 50 of selected HEAT CFM rate If fan is set to OFF on thermostat fan runs at HEAT or COOL CFM settings Constant Low Fan Circulation Fan may be run at a low rate using system switch 4 as follows OFF fan runs at rate set by HEAT CFM switch ON fan runs at 50 of rate set by HEAT CFM switch Pump Exerciser The circulating pump is exercised for 1 min every 24 hr wh...

Page 27: ...face of the heating coil Fan and Motor Check fan for dust once a year If dirty vacuum or wash to remove dust Keeping the fan blades clean will reduce noise and improve capacity and efficiency of the heating system Control and Blower Assembly Removal 1 Turn off main power 2 Disconnect power thermostat and any other miscellaneous wiring from the control board and remove them from the control casing ...

Page 28: ...nd may need re purging If the heat source is a water heater check to make sure branch connections for the heating loop are horizontal to prevent the collecting of air in the loop Water heater temperature and pressure relief valve is weeping A check valve or back flow preventer may have been installed in the system Some form of pressure relief may be required Consult water heater manufacturer s ins...

Page 29: ...eck valve repair or replace valve Fan runs for cooling but not for heating The room thermostat may be connected improperly Refer to Electrical section or wiring schematic on ecosmart for proper installation Heating during standby mode Probable cause is thermal siphoning WARRANTY Warranty is 2 years parts Visit ecosmartair com warranty htm for full details ...