USER INSTRUCTIONS

 

 

3

Starting - up the boiler 

 

Open the gas Isolation valve located under the boiler. 

 

Switch  on  the  boiler  by  placing  the  ON/OFF  switch  (1) 
in the ON position (see “Control panel”). 

 

The  boiler  will  light  automatically  (with  the  WINTER 
mode selected and room thermostat connected). 

 

Check  that  there  are  no  flashing  numbers  on  the 
display 8 (see error codes). If code H2O appears on the 
display  8  this  denotes  that  there  is  no  water  in  the 
boiler.  Consequently,  fill  the  system  as  described  in 
section “Filling the system”. 

 

 

  “WINTER” mode 

To switch boiler operation to “WINTER” mode, press button 6 (see fig. 1). The boiler will only work for the central 

heating  system.  The  “WINTER”  mode  setting  of  the  boiler  is  signalled  by  the  symbol

 

lit  continuously  on  the 

control panel. 

The automatic ignition system will light the burner every time there is a demand for room heating. In this case, the 

symbol

 

on the control panel will flash. 

 

 

  “SUMMER-WINTER” mode  

To switch boiler operation to “SUMMER/WINTER” mode, press button 6 (see fig. 1). The boiler will work for both 
central  heating/D.H.W  systems.  The  “SUMMER/WINTER”  mode  setting  of  the  boiler  is signalled by the symbols 

 

 lit continuously on the control panel. 

The automatic ignition system will light the burner every time there is a demand for room heating or domestic hot 

water, the functioning is signalled by the symbols 

 

flashing continually on the control panel. 

 
 

  Regulating the heating temperature 

The heating temperature is regulated by knob (see fig.1). 

 

Rotating the knob anticlockwise reduces the temperature. 

 

Rotating the knob clockwise increases the temperature. 

 

The  range  of  temperature  settings  for  the  central  heating  runs  from  a  minimum  of  30°C  to  a  maximum  of  

80°C, or, in the case of low temperature operation,  from a minimum of 25°C to a maximum of 59°C. 

 
 

 

D.H.W temperature control 

 

The domestic hot water temperature is regulated by knob (see “Control panel”). 

 

Rotating the knob anticlockwise reduces the temperature. 

 

Rotating the knob clockwise increases the temperature. 

 

The range of temperature settings for the domestic hot water runs from a minimum of 35°C to a maximum  of 

60°C.

 

 

Fig. 1

 

7

6

5

4

3

2

1

8

9

Summary of Contents for Ekoflux RK 34/B

Page 1: ...D ING MAN UT 1104A DIGITECH 2 REGNO UNITO EXTRAHEAT CBD Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RKA 24 8 RKA 24 RKA 28 RKA 34 Wall mounted...

Page 2: ......

Page 3: ...th current standards and where the minimum external temperature does not fall below 10 C The manufacturer will not be held responsible for installation in locations where the temperature falls to belo...

Page 4: ...TROL KNOB 4 D H W TEMPERATURE BUTTON KEEP PRESSED FOR 5 SECONDS TO DISPLAY OUTSIDE TEMPERATURE ONLY WITH OPTIONAL OUTDOOR SENSOR 5 SERVICE BUTTON 6 SUMMER WINTER OR SUMMER WINTER MODE SELECTION BUTTON...

Page 5: ...MER WINTER mode press button 6 see fig 1 The boiler will work for both central heating D H W systems The SUMMER WINTER mode setting of the boiler is signalled by the symbols lit continuously on the co...

Page 6: ...have been taken call an authorised Service Centre _E01 E01 E01 E01_ Ionisation block Code E01 lit continuously on the display Check that the gas valve on the boiler and gas meter are open and that the...

Page 7: ...E22 E22_ Parameter programming request Code E22 lit continuously on the display Call the Service Centre _E35 E35 E35 E35_ Flame Detection Malfunction Code E35 lit continuously on the display Call the...