USER INSTRUCTIONS
3
Starting - up the boiler
•
Open the gas Isolation valve located under the boiler.
•
Switch on the boiler by placing the ON/OFF switch (1)
in the ON position (see “Control panel”).
•
The boiler will light automatically (with the WINTER
mode selected and room thermostat connected).
•
Check that there are no flashing numbers on the
display 8 (see error codes). If code H2O appears on the
display 8 this denotes that there is no water in the
boiler. Consequently, fill the system as described in
section “Filling the system”.
■
“WINTER” mode
To switch boiler operation to “WINTER” mode, press button 6 (see fig. 1). The boiler will only work for the central
heating system. The “WINTER” mode setting of the boiler is signalled by the symbol
lit continuously on the
control panel.
The automatic ignition system will light the burner every time there is a demand for room heating. In this case, the
symbol
on the control panel will flash.
■
“SUMMER-WINTER” mode
To switch boiler operation to “SUMMER/WINTER” mode, press button 6 (see fig. 1). The boiler will work for both
central heating/D.H.W systems. The “SUMMER/WINTER” mode setting of the boiler is signalled by the symbols
lit continuously on the control panel.
The automatic ignition system will light the burner every time there is a demand for room heating or domestic hot
water, the functioning is signalled by the symbols
flashing continually on the control panel.
■
Regulating the heating temperature
The heating temperature is regulated by knob 2 (see fig.1).
•
Rotating the knob anticlockwise reduces the temperature.
•
Rotating the knob clockwise increases the temperature.
•
The range of temperature settings for the central heating runs from a minimum of 30°C to a maximum of
80°C, or, in the case of low temperature operation, from a minimum of 25°C to a maximum of 59°C.
■
D.H.W temperature control
The domestic hot water temperature is regulated by knob 3 (see “Control panel”).
•
Rotating the knob anticlockwise reduces the temperature.
•
Rotating the knob clockwise increases the temperature.
•
The range of temperature settings for the domestic hot water runs from a minimum of 35°C to a maximum of
60°C.
Fig. 1
7
6
5
4
3
2
1
8
9
Summary of Contents for Ekoflux RK 34/B
Page 2: ......