18
Straight Step to Radius Wall Panel
(for pool sizes 21’ and larger)
Installation Components
(item #
2890-52)
:
• (2) each Male/Female Stair Connector
• (2) 52” Standard splines for interior side of pool
• (2) each: 40 ½” Extended T splines and 10” Standard Splines for exterior side of pool
• 3/8” HHCS Bolts and Nuts; 3/8” and Backer Washers
• (2) A-Frames for connection to T Splines on either side of step
Position the female stair connector on the step flange, making sure it is level and meets the top of the pool panel.
Hold in place with vise grips or C-clamps. Using a 7/16” drill bit, drill through the step flange at the holes in the
female stair connector. Bolt the adapter plate on to the step flange using the backer washer and nut on the inside of
the step flange. Attach the male stair connector to the female stair connector at the ball joint.
Important: Keep nuts very loose until all panels are installed.
T-spline assembly / Final adjusting
The extended T-spline is installed on the exterior side of the pool, with holes to attach the the A-frame components.
The 10” standard spline is installed on top of the T-spline. The 52” standard spline is installed on the interior side of
the round pool.
Final adjusting of the step is done after all the panels are
installed and stair adapter kit nuts are tightened. Check
panel joints and step ends for proper location –using
the radius of the pool from the established center
point of the pool.
Encase the base of the pool and step with a
concrete collar. See concrete requirements
on page 21.
T-Spline
Radius Wall Panel
Male Stair
Connector
Female Stair Connector
"
x
1" Bolt
" Washer
" Nut
Backer Washer
Stair Flange
Compression Seam
Standard Spline
INGROUND: WALK-IN STEP INSTALLATION
POOL EXTERIOR
STEP INTERIOR
Note:
Remember to
remove stair gaskets
and faceplates
before installing the